{"title":"Cells \u0026 Electrodes","description":"","products":[{"product_id":"basic-electrochemical-cell-setup","title":"BASIC ELECTROCHEMICAL CELL SETUP","description":"\u003cp data-mce-fragment=\"1\"\u003eThis is a stationary solution basic electrochemical cell for measurements of electrodes in a form of: a) rod\/disc (6 mm dia.), b) thin film deposited on a flat substrate (using a wire clip) and c) membrane (using a wire clip). The working, counter, and reference electrodes are mounted in a top casing either in 2-, or 3-electrode setup. The cell elements are constructed with materials that are inert to the sample (glass and PEEK). It well fits aqueous (FKM\/EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight and can be used when the removal and exclusion of contaminants such as oxygen and water is required by bubbling of an inert gas through the electrolyte. The cell chamber is available in several material variants \u003ca data-mce-fragment=\"1\" title=\"cell chamber\" href=\"https:\/\/wholesale.redox.me\/collections\/accessories\/products\/50-ml-cell-chamber\" target=\"_blank\" data-mce-href=\"https:\/\/wholesale.redox.me\/collections\/accessories\/products\/50-ml-cell-chamber\"\u003ehere\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication note:\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe reference electrode tip should be placed at the level of working electrode center. This will ensure a low potential drop throughout the electrolyte solution for low-current experiment. Various auxiliary electrodes are suitable for this cell including metal wire and metal foil electrodes as well as graphite rod. The bubbling of gas through the solution must be stopped prior to experiment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecification:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003emaximum electrolyte volume: 50 mL\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eelectrode plug diameter: 6 mm\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enumber of electrode slots: 3\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eIntrastat data:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eHS Code: 90309000\u003cbr data-mce-fragment=\"1\"\u003eCountry of Origin: Sweden\u003cbr data-mce-fragment=\"1\"\u003eNET weight: 200 g\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSetup includes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-hyzs{background-color:#D6D6D6;border-color:inherit;font-weight:bold;text-align:left;vertical-align:middle}\n.tg .tg-wjcf{background-color:#EFEFEF;text-align:left;vertical-align:middle}\n.tg .tg-ha5p{background-color:#D6D6D6;font-weight:bold;text-align:left;vertical-align:middle}\n.tg .tg-zr06{background-color:#FFF;text-align:left;vertical-align:middle}\n.tg .tg-ktyi{background-color:#FFF;text-align:left;vertical-align:top}\n--\u003e\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-hyzs\"\u003e\u003cspan style=\"font-weight: bold; color: #000; background-color: #d6d6d6;\"\u003eItem\u003c\/span\u003e\u003c\/th\u003e\n\u003cth class=\"tg-ha5p\"\u003e\u003cspan style=\"font-weight: bold; color: #000; background-color: #d6d6d6;\"\u003eQty\u003c\/span\u003e\u003c\/th\u003e\n\u003cth class=\"tg-ha5p\"\u003e\u003cspan style=\"font-weight: bold; color: #000; background-color: #d6d6d6;\"\u003eB-A-BEC-50\u003c\/span\u003e\u003c\/th\u003e\n\u003cth class=\"tg-ha5p\"\u003e\u003cspan style=\"font-weight: bold; color: #000; background-color: #d6d6d6;\"\u003eB-O-BEC-50\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-zr06\"\u003eBEC 50 mL - Basic Electrochemical Cell\u003c\/td\u003e\n\u003ctd class=\"tg-zr06\"\u003e1\u003c\/td\u003e\n\u003ctd class=\"tg-zr06\"\u003eC-A-BEC-50\u003c\/td\u003e\n\u003ctd class=\"tg-zr06\"\u003eC-O-BEC-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wjcf\"\u003eMetal wire auxiliary electrode – 50HX15 0.6\/250 mm, platinum (99,9%), 1 mm dia. gold plated pin\u003c\/td\u003e\n\u003ctd class=\"tg-wjcf\"\u003e1\u003c\/td\u003e\n\u003ctd class=\"tg-wjcf\"\u003eE-A-50HX15_Pt-1mm\u003c\/td\u003e\n\u003ctd class=\"tg-wjcf\"\u003eE-O-50HX15_Pt-1mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-zr06\"\u003eSilver \/ Silver Chloride Reference Electrode - Ag\/AgCl 70 mm\u003c\/td\u003e\n\u003ctd class=\"tg-zr06\"\u003e1\u003c\/td\u003e\n\u003ctd class=\"tg-zr06\"\u003eE-Ag\/AgCl_70\u003c\/td\u003e\n\u003ctd class=\"tg-ktyi\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wjcf\"\u003eNon-aqueous Silver \/ Silver Ion Reference Electrode - Ag\/Ag+ 70 mm\u003c\/td\u003e\n\u003ctd class=\"tg-wjcf\"\u003e1\u003c\/td\u003e\n\u003ctd class=\"tg-wjcf\"\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-wjcf\"\u003eE-Ag\/Ag+_70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-zr06\"\u003eWorking disk electrode - 2 mm dia., PEEK BODY 6 mm dia. - 70 mm, glassy carbon\u003c\/td\u003e\n\u003ctd class=\"tg-zr06\"\u003e1\u003c\/td\u003e\n\u003ctd class=\"tg-zr06\"\u003eE-A-DISK_GC-70\u003c\/td\u003e\n\u003ctd class=\"tg-zr06\"\u003eE-O-DISK_GC-70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wjcf\"\u003e10 pcs of Tantalum wire clip with septum plug 0.6 mm dia., 60 mm long\u003c\/td\u003e\n\u003ctd class=\"tg-wjcf\"\u003e1\u003c\/td\u003e\n\u003ctd class=\"tg-wjcf\"\u003eE-A-Ta_CLIP-0.6\/60-10p\u003c\/td\u003e\n\u003ctd class=\"tg-wjcf\"\u003eE-O-Ta_CLIP-0.6\/60-10p\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Redoxme","offers":[{"title":"Aqueous electrolyte experiment","offer_id":43364837392565,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment","offer_id":43364837425333,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/3_540x_b6bac446-3331-4903-adac-7d531f728a93.png?v=1701301166"},{"product_id":"ptfe-basic-electrochemical-cell-setup","title":"PTFE BASIC ELECTROCHEMICAL CELL SETUP","description":"\u003cp data-mce-fragment=\"1\"\u003eThis cell is a sister version of\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/redox.me\/collections\/electrochemical-cells\/products\/bec-50-ml-basic-electrochemical-cell\" title=\"basic electrochemical cell\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/redox.me\/collections\/electrochemical-cells\/products\/bec-50-ml-basic-electrochemical-cell\" target=\"_blank\"\u003eBEC 50 mL\u003c\/a\u003e. In this cell concept, all elements that stay in contact with an electrolyte or its fumes are made of PTFE and other fluorinated materials (tubing, fittings, and O-Rings). This cell is used wherever PEEK fails,\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cem data-mce-fragment=\"1\"\u003ei.e.\u003c\/em\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ewhen using electrolytes containing:\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAqua regia - HNO3 + HCl\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eBenzenesulfonic acid - aqueous C6H5SO3H\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eBromine (liquid) - pure Br2\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCarbolic Acid (Phenol) - C6H5OH\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCarbon Disulfide - CS2\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eChlorine (aqueous and anhydrous liquid) - Cl2\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eChlorosulfonic acid - pure ClSO3H\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eChromic Acid - aqueous H2CrO4 \u0026gt;50%\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEthylene bromide (anhydrous) - pure CH2CHBr\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFuming sulphuric acid (Oleum) - pure H2SO\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eHydrobromic acid - aqueous HBr\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eHydrofluoric acid - concentrated aqueous HF\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eNitric acid - aqueous HNO3 \u0026gt;50%\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eSulphuric acid - concentrated (96%) H2SO4\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eSulphurous acid - aqueous H2SO3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe chamber is also alkali-resistant, so it can be used instead of glass in experiments including high pH hot electrolytes. A full description of the difference between PEEK and PTFE cells can be found in our\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca title=\"when PTFE is better than PEEK\" href=\"https:\/\/redox.me\/blogs\/good-measurement-practices\/when-ptfe-is-better-than-peek\" data-mce-fragment=\"1\" target=\"_blank\" data-mce-href=\"https:\/\/redox.me\/blogs\/good-measurement-practices\/when-ptfe-is-better-than-peek\"\u003eblog post\u003c\/a\u003e. \u003cbr data-mce-fragment=\"1\"\u003eThis is a stationary solution basic electrochemical (electrolytic) cell for measurements of electrodes in a form of: a) rod\/disc (6 mm dia.), b) thin film deposited on flat substrate (using a\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/redox.me\/products\/10-pcs-of-tantalum-wire-clip-with-septum-plug?_pos=1\u0026amp;_sid=957c1ee81\u0026amp;_ss=r\" title=\"electrode wire clip\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/redox.me\/products\/10-pcs-of-tantalum-wire-clip-with-septum-plug?_pos=1\u0026amp;_sid=957c1ee81\u0026amp;_ss=r\" target=\"_blank\"\u003ewire clip\u003c\/a\u003e) and c) membrane (using a\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/redox.me\/products\/10-pcs-of-tantalum-wire-clip-with-septum-plug?_pos=1\u0026amp;_sid=957c1ee81\u0026amp;_ss=r\" title=\"electrode wire clip\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/redox.me\/products\/10-pcs-of-tantalum-wire-clip-with-septum-plug?_pos=1\u0026amp;_sid=957c1ee81\u0026amp;_ss=r\" target=\"_blank\"\u003ewire clip\u003c\/a\u003e). The working,\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/redox.me\/collections\/metal-wire-auxiliary-electrodes\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/redox.me\/collections\/metal-wire-auxiliary-electrodes\" target=\"_blank\"\u003ecounter\u003c\/a\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eand\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/redox.me\/collections\/reference-electrodes\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/redox.me\/collections\/reference-electrodes\" target=\"_blank\"\u003ereference electrodes\u003c\/a\u003e are mounted in a top casing either in 2-, or 3-electrode setup. When the reference electrode has a glass body, a\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/redox.me\/products\/liquid-junction-adapter-6-mm-dia?_pos=1\u0026amp;_sid=abcf1cac3\u0026amp;_ss=r\u0026amp;variant=46770650710341\" title=\"double junction elelctrode\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/redox.me\/products\/liquid-junction-adapter-6-mm-dia?_pos=1\u0026amp;_sid=abcf1cac3\u0026amp;_ss=r\u0026amp;variant=46770650710341\" target=\"_blank\"\u003eliquid junction adapter\u003c\/a\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eis needed. The cell elements are constructed with materials that are inert to the sample (PTFE). It well fits aqueous (FKM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight and can be used when the removal and exclusion of contaminants such as oxygen and water is required by bubbling of an inert gas through the electrolyte. \u003cspan data-mce-fragment=\"1\"\u003eThe cell chamber is available in several material variants \u003c\/span\u003e\u003ca title=\"cell chamber\" href=\"https:\/\/redox.me\/collections\/accessories\/products\/50-ml-cell-chamber\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/redox.me\/collections\/accessories\/products\/50-ml-cell-chamber\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003cspan data-mce-fragment=\"1\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication note:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eThe\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/redox.me\/collections\/reference-electrodes\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/redox.me\/collections\/reference-electrodes\" target=\"_blank\"\u003ereference electrode\u003c\/a\u003e (or liquid junction adapter insertion tube) tip should be placed at the level of the working electrode center. This will ensure a low potential drop throughout the electrolyte solution for low-current experiments. Various auxiliary electrodes are suitable for this cell including\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/redox.me\/collections\/metal-wire-auxiliary-electrodes\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/redox.me\/collections\/metal-wire-auxiliary-electrodes\" target=\"_blank\"\u003emetal wire\u003c\/a\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eand metal foil electrodes as well as\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/redox.me\/collections\/non-metal-auxiliary-electrodes\/products\/graphite-rod-electrode-6-70-mm\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/redox.me\/collections\/non-metal-auxiliary-electrodes\/products\/graphite-rod-electrode-6-70-mm\" target=\"_blank\"\u003egraphite rod\u003c\/a\u003e. The bubbling of gas through the solution must be stopped prior to experiment.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eA typical cell setup configuration for strong acidic electrolytes includes:\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca title=\"Electrochemical cell for strong acidic electrolytes\" href=\"https:\/\/redox.me\/collections\/electrochemical-cells\/products\/ptfe-bec-50-ml-ptfe-basic-electrochemical-cell-1\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/redox.me\/collections\/electrochemical-cells\/products\/ptfe-bec-50-ml-ptfe-basic-electrochemical-cell-1\" target=\"_blank\"\u003ePTFE Basic Electrochemical Cell 50 mL\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/redox.me\/collections\/metal-wire-auxiliary-electrodes\/products\/metal-wire-auxiliary-electrode-ptfe-50hx15-0-6-250-mm\" title=\"counter electrode\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/redox.me\/collections\/metal-wire-auxiliary-electrodes\/products\/metal-wire-auxiliary-electrode-ptfe-50hx15-0-6-250-mm\" target=\"_blank\"\u003ePTFE 50HX15 0.6\/250 wire counter electrode, Platinum\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/redox.me\/collections\/working-electrodes-current-collectors\/products\/10-pcs-of-metal-wire-clip-nad-ptfe-plug-with-expanded-ptfe-septum\" title=\"elelctrode clip\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/redox.me\/collections\/working-electrodes-current-collectors\/products\/10-pcs-of-metal-wire-clip-nad-ptfe-plug-with-expanded-ptfe-septum\" target=\"_blank\"\u003e10 pcs of Stainless Steel 316L wire clip with PTFE septum plug\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca title=\"Double junction reference electrode\" href=\"https:\/\/redox.me\/products\/liquid-junction-adapter-6-mm-dia?_pos=1\u0026amp;_sid=3908b6d80\u0026amp;_ss=r\u0026amp;variant=46770717851973\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/redox.me\/products\/liquid-junction-adapter-6-mm-dia?_pos=1\u0026amp;_sid=3908b6d80\u0026amp;_ss=r\u0026amp;variant=46770717851973\" target=\"_blank\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eLiquid Junction adapter with membrane mount\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca title=\"Ag\/AgCl RE\" href=\"https:\/\/redox.me\/products\/silver-silver-chloride-reference-electrode-ag-agcl-30mm?_pos=2\u0026amp;_sid=d1ea38369\u0026amp;_ss=r\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/redox.me\/products\/silver-silver-chloride-reference-electrode-ag-agcl-30mm?_pos=2\u0026amp;_sid=d1ea38369\u0026amp;_ss=r\" target=\"_blank\"\u003eAg\/AgCl 30 mm Silver \/ Silver Chrolide reference electrode\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca title=\"PTFE membrane\" href=\"https:\/\/redox.me\/products\/ptfe-membrane-hydrophilic-25-mm-dia-pack-of-10?_pos=6\u0026amp;_sid=8334af5a2\u0026amp;_ss=r\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/redox.me\/products\/ptfe-membrane-hydrophilic-25-mm-dia-pack-of-10?_pos=6\u0026amp;_sid=8334af5a2\u0026amp;_ss=r\" target=\"_blank\"\u003e\u003cspan data-mce-fragment=\"1\"\u003ePTFE membranes (PVDF in case of HF)\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eA typical cell setup configuration for strong (hot) alkaline electrolytes includes:\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca title=\"electrochemical cell for strong alkaline electrolytes\" href=\"https:\/\/redox.me\/collections\/electrochemical-cells\/products\/ptfe-bec-50-ml-ptfe-basic-electrochemical-cell-1\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/redox.me\/collections\/electrochemical-cells\/products\/ptfe-bec-50-ml-ptfe-basic-electrochemical-cell-1\" target=\"_blank\"\u003e\u003cspan data-mce-fragment=\"1\"\u003ePTFE Basic Electrochemical Cell 50 mL\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/redox.me\/collections\/metal-wire-auxiliary-electrodes\/products\/metal-wire-auxiliary-electrode-ptfe-50hx15-0-6-250-mm\" title=\"counter electrode\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/redox.me\/collections\/metal-wire-auxiliary-electrodes\/products\/metal-wire-auxiliary-electrode-ptfe-50hx15-0-6-250-mm\" target=\"_blank\"\u003e\u003cspan data-mce-fragment=\"1\"\u003ePTFE 50HX15 0.6\/250 wire counter electrode, Platinum\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/redox.me\/collections\/working-electrodes-current-collectors\/products\/10-pcs-of-metal-wire-clip-nad-ptfe-plug-with-expanded-ptfe-septum\" title=\"electrode clip\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/redox.me\/collections\/working-electrodes-current-collectors\/products\/10-pcs-of-metal-wire-clip-nad-ptfe-plug-with-expanded-ptfe-septum\" target=\"_blank\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e10 pcs of Stainless Steel 316L wire clip with PTFE septum plug\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003ca title=\"Double junction referece electrode for strong alkaline electrolytes\" href=\"https:\/\/redox.me\/products\/liquid-junction-adapter-6-mm-dia?_pos=1\u0026amp;_sid=3908b6d80\u0026amp;_ss=r\u0026amp;variant=46770717851973\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/redox.me\/products\/liquid-junction-adapter-6-mm-dia?_pos=1\u0026amp;_sid=3908b6d80\u0026amp;_ss=r\u0026amp;variant=46770717851973\" target=\"_blank\"\u003eLiquid Junction adapter with membrane mount\u003c\/a\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eHg\/HgO 30 mm Mercury \/ Mercury Oxide reference electrode\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003ca title=\"PTFE membrane\" href=\"https:\/\/redox.me\/products\/ptfe-membrane-hydrophilic-25-mm-dia-pack-of-10?_pos=6\u0026amp;_sid=8334af5a2\u0026amp;_ss=r\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/redox.me\/products\/ptfe-membrane-hydrophilic-25-mm-dia-pack-of-10?_pos=6\u0026amp;_sid=8334af5a2\u0026amp;_ss=r\" target=\"_blank\"\u003ePTFE membranes\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecification\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003emaximum electrolyte volume: 35 mL\u003cbr data-mce-fragment=\"1\"\u003eelectrode plug diameter: 6 mm\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eIntrastat data\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eHS Code: 90309000\u003cbr data-mce-fragment=\"1\"\u003eCountry of Origin: Sweden\u003cbr data-mce-fragment=\"1\"\u003eNET weight: 200g\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSetup includes:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e1 x PTFE Basic electrochemical cell - PTFE BEC 50 mL\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e1 x PTFE lid\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e1 x PTFE chamber\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e1 x PTFE plug\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e1 x PTFE 50HX15 0.6\/250 wire counter electrode, Platinum\u003cbr data-mce-fragment=\"1\"\u003e1 x Reference electrode\u003cbr data-mce-fragment=\"1\"\u003e1 x 10 pcs of Stainless Steel 316L wire clip with PTFE septum plug\u003c\/p\u003e","brand":"Redoxme","offers":[{"title":"Aqueous electrolyte experiment","offer_id":43364928094389,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment","offer_id":43364928127157,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/1_540x_d63d876b-2d8e-410e-8710-60d15c9ce197.png?v=1701303274"},{"product_id":"standard-electrochemical-cell-setup","title":"STANDARD ELECTROCHEMICAL CELL SETUP","description":"\u003cp data-mce-fragment=\"1\"\u003eThis is a stationary solution standard electrochemical (electrolytic) cell for measurements of electrodes in a form of: a) rod\/disc (6 mm dia.), b) thin film deposited on a flat substrate (using a\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca title=\"Sample holder\" href=\"https:\/\/wholesale.redox.me\/collections\/holders-adapters\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/wholesale.redox.me\/collections\/holders-adapters\" target=\"_blank\"\u003esample holder\u003c\/a\u003e) and c) free-standing membrane (using the\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/wholesale.redox.me\/collections\/holders-adapters\/products\/basic-sample-holder-tantalum-contact-4-mm-max-thickness\" title=\"sample holder\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/wholesale.redox.me\/collections\/holders-adapters\/products\/basic-sample-holder-tantalum-contact-4-mm-max-thickness\" target=\"_blank\"\u003ebasic sample holder\u003c\/a\u003e). The\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/wholesale.redox.me\/collections\/holders-adapters\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/wholesale.redox.me\/collections\/holders-adapters\" target=\"_blank\"\u003eworking\u003c\/a\u003e,\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/wholesale.redox.me\/collections\/metal-auxiliary-electrodes\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/wholesale.redox.me\/collections\/metal-auxiliary-electrodes\" target=\"_blank\"\u003ecounter\u003c\/a\u003e, and\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/wholesale.redox.me\/collections\/reference-electrodes\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/wholesale.redox.me\/collections\/reference-electrodes\" target=\"_blank\"\u003ereference electrodes\u003c\/a\u003e are mounted in a top casing either in 2-, or 3-electrode setup. The cell has two spare ports for connection of\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cem data-mce-fragment=\"1\"\u003ee.g.\u003c\/em\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ethermometer, Clark electrode, pH meter electrode, or other 6 mm dia. electrode\/probe. \u003cbr data-mce-fragment=\"1\"\u003eThe cell elements are constructed with materials that are inert to the sample (glass and PEEK). It well fits aqueous (EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight and can be used when the removal and exclusion of contaminants such as oxygen and water is required by bubbling of an inert gas through the electrolyte.\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe jacketed model is available \u003ca title=\"jacketed standard electrochemical cell\" href=\"https:\/\/wholesale.redox.me\/collections\/electrochemical-cell-setups\/products\/jacketed-standard-electrochemical-cell-setup\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/wholesale.redox.me\/collections\/electrochemical-cell-setups\/products\/jacketed-standard-electrochemical-cell-setup\" target=\"_blank\"\u003ehere\u003c\/a\u003e. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication note\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eThe\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/wholesale.redox.me\/collections\/reference-electrodes\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/wholesale.redox.me\/collections\/reference-electrodes\" target=\"_blank\"\u003ereference electrode\u003c\/a\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003etip should be placed close to a working electrode center. This will ensure a low potential drop throughout the electrolyte solution for low-current experiment. Various auxiliary electrodes are suitable for this cell including\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/wholesale.redox.me\/collections\/metal-auxiliary-electrodes\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/wholesale.redox.me\/collections\/metal-auxiliary-electrodes\" target=\"_blank\"\u003emetal wire\u003c\/a\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eand metal foil electrodes as well as\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/wholesale.redox.me\/collections\/non-metal-electrodes\/products\/graphite-rod-electrode-gr-6-70-mm\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/wholesale.redox.me\/collections\/non-metal-electrodes\/products\/graphite-rod-electrode-gr-6-70-mm\" target=\"_blank\"\u003egraphite rod\u003c\/a\u003e. The bubbling of gas through the solution must be stopped prior to experiment.\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eOperating Video Manual:\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"video-wrapper\" data-mce-fragment=\"1\"\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/ge2VVcWcT3w\" title=\"YouTube video player\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/www.youtube.com\/embed\/ge2VVcWcT3w\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecification:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003emaximum electrolyte volume: 100, 150, 200, 250, 350, 500 or 1000 mL\u003cbr data-mce-fragment=\"1\"\u003eelectrode plug diameter: 6 mm\u003cbr data-mce-fragment=\"1\"\u003enumber of electrode ports: 5\u003cbr data-mce-fragment=\"1\"\u003evial material: borosilicate 3.3 glass\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eIntrastat data:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eHS Code: 90309000\u003cbr data-mce-fragment=\"1\"\u003eCountry of Origin: Sweden\u003cbr data-mce-fragment=\"1\"\u003eNET weight: 200 g (100, 150 mL), 300 g (200, 250, 350 mL), 400 g (500 mL), 600 g (1000 mL)\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSetup includes:\n  \u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-ekg0{background-color:#EFEFEF;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-lw2o{background-color:#EFEFEF;font-weight:bold;text-align:left;vertical-align:middle}\n.tg .tg-hyzs{background-color:#D6D6D6;border-color:inherit;font-weight:bold;text-align:left;vertical-align:middle}\n.tg .tg-ha5p{background-color:#D6D6D6;font-weight:bold;text-align:left;vertical-align:middle}\n.tg .tg-dgl5{background-color:#FFF;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-zr06{background-color:#FFF;text-align:left;vertical-align:middle}\n\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n  \u003ctr\u003e\n    \u003cth class=\"tg-hyzs\"\u003e\u003c\/th\u003e\n    \u003cth class=\"tg-ha5p\"\u003e\u003cspan style=\"font-weight:bold;color:#000;background-color:#D6D6D6\"\u003eredox.me EC cell\u003c\/span\u003e\u003c\/th\u003e\n    \u003cth class=\"tg-ha5p\"\u003e\u003cspan style=\"font-weight:bold;color:#000;background-color:#D6D6D6\"\u003ereference electrode\u003c\/span\u003e\u003c\/th\u003e\n    \u003cth class=\"tg-ha5p\"\u003e\u003cspan style=\"font-weight:bold;color:#000;background-color:#D6D6D6\"\u003ecounter electrode\u003c\/span\u003e\u003c\/th\u003e\n    \u003cth class=\"tg-ha5p\"\u003e\u003cspan style=\"font-weight:bold;color:#000;background-color:#D6D6D6\"\u003eWE holder\u003c\/span\u003e\u003c\/th\u003e\n  \u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n  \u003ctr\u003e\n    \u003ctd class=\"tg-dgl5\"\u003e\n\u003cspan style=\"font-weight:700\"\u003eB-A-STD_EC-100\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight:700\"\u003eB-A-STD_EC-150\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight:700\"\u003eB-A-STD_EC-200\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight:700\"\u003eB-A-STD_EC-250\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight:700\"\u003eB-A-STD_EC-350\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight:700\"\u003eB-A-STD_EC-500\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight:700\"\u003eB-A-STD_EC-1L\u003c\/span\u003e\n\u003c\/td\u003e\n    \u003ctd class=\"tg-zr06\"\u003eC-A-STD_EC-100\u003cbr\u003e\u003cbr\u003eC-A-STD_EC-150\u003cbr\u003e\u003cbr\u003eC-A-STD_EC-200\u003cbr\u003e\u003cbr\u003eC-A-STD_EC-250\u003cbr\u003e\u003cbr\u003eC-A-STD_EC-350\u003cbr\u003e\u003cbr\u003eC-A-STD_EC-500\u003cbr\u003e\u003cbr\u003eC-A-STD_EC-1L\u003c\/td\u003e\n    \u003ctd class=\"tg-zr06\"\u003eE-Ag\/AgCl_70\u003c\/td\u003e\n    \u003ctd class=\"tg-zr06\"\u003eE-A-50HX15_Pt-1mm,\u003cbr\u003e\u003cbr\u003eE-A-Gr_6\/70\u003c\/td\u003e\n    \u003ctd class=\"tg-zr06\"\u003eH-A-S_HOLD-25x25-11.3dia\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd class=\"tg-ekg0\"\u003e\n\u003cspan style=\"font-weight:700\"\u003eB-O-STD_EC-100\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight:700\"\u003eB-O-STD_EC-150\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight:700\"\u003eB-O-STD_EC-200\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight:700\"\u003eB-O-STD_EC-250\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight:700\"\u003eB-O-STD_EC-350\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight:700\"\u003eB-O-STD_EC-500\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight:700\"\u003eB-O-STD_EC-1L\u003c\/span\u003e\n\u003c\/td\u003e\n    \u003ctd class=\"tg-lw2o\"\u003e\n\u003cspan style=\"font-weight:500;font-style:normal;color:#000\"\u003eC-O-STD_EC-100\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight:500;font-style:normal;color:#000\"\u003eC-O-STD_EC-150\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight:500;font-style:normal;color:#000\"\u003eC-O-STD_EC-200\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight:500;font-style:normal;color:#000\"\u003eC-O-STD_EC-250\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight:500;font-style:normal;color:#000\"\u003eC-O-STD_EC-350\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight:500;font-style:normal;color:#000\"\u003eC-O-STD_EC-500\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight:500;font-style:normal;color:#000\"\u003eC-O-STD_EC-1L\u003c\/span\u003e\n\u003c\/td\u003e\n    \u003ctd class=\"tg-lw2o\"\u003e\u003cspan style=\"font-weight:500;font-style:normal;color:#000\"\u003eE-Ag\/Ag+_70\u003c\/span\u003e\u003c\/td\u003e\n    \u003ctd class=\"tg-lw2o\"\u003e\n\u003cspan style=\"font-weight:500;font-style:normal;color:#000\"\u003eE-O-50HX15_Pt-1mm,\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight:500;font-style:normal;color:#000\"\u003eE-O-Gr_6\/70\u003c\/span\u003e\n\u003c\/td\u003e\n    \u003ctd class=\"tg-lw2o\"\u003e\u003cspan style=\"font-weight:500;font-style:normal;color:#000\"\u003eH-O-S_HOLD-25x25-11.3dia\u003c\/span\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Redoxme","offers":[{"title":"Aqueous electrolyte experiment","offer_id":43364932681909,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment","offer_id":43364932714677,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/STDECCELL_540x_009520ec-3b90-4d46-a70c-f120b82ba8c8.png?v=1701303557"},{"product_id":"jacketed-standard-electrochemical-cell-setup","title":"JACKETED STANDARD ELECTROCHEMICAL CELL SETUP","description":"\u003cdiv data-mce-fragment=\"1\" class=\"product-description rte\" itemprop=\"description\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis is a stationary solution jacketed standard electrochemical (electrolytic) cell for measurements of electrodes in a form of: a) rod\/disc (6 mm dia.), b) thin film deposited on a flat substrate (using a\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca data-mce-fragment=\"1\" title=\"Sample holder\" href=\"https:\/\/wholesale.redox.me\/collections\/holders-adapters\" target=\"_blank\" data-mce-href=\"https:\/\/wholesale.redox.me\/collections\/holders-adapters\"\u003esample holder\u003c\/a\u003e) and c) membrane (using a clip electrode). The\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca data-mce-fragment=\"1\" href=\"https:\/\/wholesale.redox.me\/collections\/holders-adapters\" target=\"_blank\" data-mce-href=\"https:\/\/wholesale.redox.me\/collections\/holders-adapters\"\u003eworking\u003c\/a\u003e,\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca data-mce-fragment=\"1\" href=\"https:\/\/wholesale.redox.me\/collections\/metal-auxiliary-electrodes\" target=\"_blank\" data-mce-href=\"https:\/\/wholesale.redox.me\/collections\/metal-auxiliary-electrodes\"\u003ecounter\u003c\/a\u003e, and\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca data-mce-fragment=\"1\" href=\"https:\/\/wholesale.redox.me\/collections\/reference-electrodes\" target=\"_blank\" data-mce-href=\"https:\/\/wholesale.redox.me\/collections\/reference-electrodes\"\u003ereference electrodes\u003c\/a\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eare mounted in a top casing either in 2-, or 3-electrode setup. A temperature of an electrolyte can be controlled by circulation of a fluid agent between thermostatic bath and the jacketed vial. The cell has two spare ports for connection of\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cem data-mce-fragment=\"1\"\u003ee.g.\u003c\/em\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ethermometer, Clark electrode, pH meter electrode, or other 6 mm dia. electrode\/probe. \u003cbr data-mce-fragment=\"1\"\u003eThe cell elements are constructed with materials that are inert to the sample (glass and PEEK). It well fits aqueous (EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight and can be used when the removal and exclusion of contaminants such as oxygen and water is required by bubbling of inert gas through the electrolyte. The non-jacketed model is available \u003ca data-mce-fragment=\"1\" title=\"standard electrochemical cell\" href=\"https:\/\/wholesale.redox.me\/collections\/electrochemical-cell-setups\/products\/standard-electrochemical-cell-setup\" target=\"_blank\" data-mce-href=\"https:\/\/wholesale.redox.me\/collections\/electrochemical-cell-setups\/products\/standard-electrochemical-cell-setup\"\u003ehere\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication note:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eThe\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca data-mce-fragment=\"1\" href=\"https:\/\/wholesale.redox.me\/collections\/reference-electrodes\" target=\"_blank\" data-mce-href=\"https:\/\/wholesale.redox.me\/collections\/reference-electrodes\"\u003ereference electrode\u003c\/a\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003etip should be placed close to a working electrode center. This will ensure a low potential drop throughout the electrolyte solution for low-current experiment. Various auxiliary electrodes are suitable for this cell including\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca data-mce-fragment=\"1\" href=\"https:\/\/wholesale.redox.me\/collections\/metal-auxiliary-electrodes\" target=\"_blank\" data-mce-href=\"https:\/\/wholesale.redox.me\/collections\/metal-auxiliary-electrodes\"\u003emetal wire\u003c\/a\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eand metal foil electrodes as well as\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca data-mce-fragment=\"1\" href=\"https:\/\/wholesale.redox.me\/collections\/electrodes\/products\/graphite-rod-electrode-gr-6-70-mm\" target=\"_blank\" data-mce-href=\"https:\/\/wholesale.redox.me\/collections\/electrodes\/products\/graphite-rod-electrode-gr-6-70-mm\"\u003egraphite rod\u003c\/a\u003e. The bubbling of gas through the solution must be stopped prior to experiment.\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eOperating Video Manual:\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv data-mce-fragment=\"1\" class=\"video-wrapper\"\u003e\u003ciframe data-mce-fragment=\"1\" title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/ge2VVcWcT3w\" height=\"315\" width=\"560\" allowfullscreen=\"\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" frameborder=\"0\" data-mce-src=\"https:\/\/www.youtube.com\/embed\/ge2VVcWcT3w\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecification:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003emaximum electrolyte volume: 100, 150, 200, 250, 350, 500 or 1000 mL\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eelectrode plug diameter: 6 mm\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003enumber of electrode ports: 5\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003evial material: borosilicate 3.3 glass\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003ehose connector type: multi barb\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003erecommended tube size: ID 8.0 mm\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eIntrastat data:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eHS Code: 90309000\u003cbr data-mce-fragment=\"1\"\u003eCountry of Origin: Sweden\u003cbr data-mce-fragment=\"1\"\u003eNET weight: 200g (100, 150 mL), 300g (200, 250, 350 mL), 600g (500 mL), 1100g (1000 mL)\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSetup includes:\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e1 x\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eJacketed Standard Electrochemical Cell - JACKETED STD EC CELL\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e1 x\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eMetal Wire Auxiliary Electrode - 50HX15 0.6\/250 mm (Platinum)\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e1 x \u003cspan data-mce-fragment=\"1\"\u003eGraphite rod electrode - GR 6\/70 mm\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e1 x Reference electrode (Ag\/AgCl, or Ag\/Ag+)\u003cbr data-mce-fragment=\"1\"\u003e1 x Sample Holder 25 mm x 25 mm\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Redoxme","offers":[{"title":"Aqueous electrolyte experiment","offer_id":43364941627573,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment","offer_id":43364941660341,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/JACKETEDSTDECCELL_540x_56b0c28e-cbea-4eea-a0e6-f2d2e5c17e12.png?v=1701304135"},{"product_id":"two-compartment-electrochemical-cell-setup","title":"TWO-COMPARTMENT ELECTROCHEMICAL CELL SETUP","description":"\u003cp data-mce-fragment=\"1\"\u003eThis is a stationary solution two-compartment electrochemical cell for measurements of electrodes in a form of: a) rod\/disc (6 mm dia.), b) thin film deposited on flat substrate (using a wire clip) and c) membrane (using a wire clip). The working, counter and reference electrodes are mounted in a top casing either in 2-, or 3-electrode setup. The counter electrode is placed in the second glass compartment separated from the other electrodes by a ceramic frit. The cell elements are constructed with materials that are inert to the sample (glass and PEEK). It well fits aqueous (\u003cspan data-mce-fragment=\"1\"\u003eFKM\/EPDM \u003c\/span\u003eO-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight and can be used when the removal and exclusion of contaminants such as oxygen and water is required by bubbling of an inert gas through the electrolyte. \u003cspan data-mce-fragment=\"1\"\u003eThe cell chamber is available in several material variants \u003c\/span\u003e\u003ca title=\"cell chamber\" href=\"https:\/\/wholesale.redox.me\/collections\/accessories\/products\/50-ml-cell-chamber\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/wholesale.redox.me\/collections\/accessories\/products\/50-ml-cell-chamber\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003cspan data-mce-fragment=\"1\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication note:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003eThe reference electrode tip should be placed at the level of working electrode center. This will ensure a low potential drop throughout the electrolyte solution for low-current experiment. Various auxiliary electrodes are suitable for this cell including metal wire and metal foil electrodes as well as graphite rod. The bubbling of gas through the solution must be stopped prior to experiment.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecification:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003emaximum electrolyte volume: 50 mL\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eelectrode plug diameter: 6 mm\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003enumber of electrode slots: 3\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eIntrastat data:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eHS Code: 90309000\u003cbr data-mce-fragment=\"1\"\u003eCountry of Origin: Sweden\u003cbr data-mce-fragment=\"1\"\u003eNET weight: 200 g\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSetup includes:\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e1 x Two-compartment Electrochemical Cell – 2-CEC 50 mL\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e1 x \u003c\/span\u003eMetal Wire Auxiliary Electrode - 50HX15 0.6\/250 mm (Platinum)\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e1 x Reference electrode (Ag\/AgCl, or Ag\/Ag+)\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e1 x \u003c\/span\u003eGlassy Carbon disk electrode – 2 mm dia.\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e1 x \u003c\/span\u003ePlug with silicone rubber septum and set of Tantalum wire clips (set of 10)\u003c\/p\u003e","brand":"Redoxme","offers":[{"title":"Aqueous electrolyte experiment","offer_id":43364948410549,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment","offer_id":43364948443317,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/3_540x_4fc1b033-a7a5-465b-b425-36330ba7cb3f.png?v=1701304854"},{"product_id":"autoclavable-two-compartment-electrochemical-cell-setup","title":"AUTOCLAVABLE TWO-COMPARTMENT ELECTROCHEMICAL CELL SETUP","description":"\u003cdiv class=\"product-description rte\" data-mce-fragment=\"1\" itemprop=\"description\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis is a stationary solution two-compartment electrochemical cell for measurements under hydrothermal conditions. It is compatible with working electrodes in a form of: a) rod\/disc (6 mm dia.), b) thin film deposited on a flat substrate (using a wire clip) and c) membrane (using a\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca title=\"tantalum clip\" href=\"https:\/\/redox.me\/collections\/working-electrodes-current-collectors\/products\/10-pcs-of-tantalum-wire-clip-with-septum-plug\" data-mce-fragment=\"1\" target=\"_blank\" data-mce-href=\"https:\/\/redox.me\/collections\/working-electrodes-current-collectors\/products\/10-pcs-of-tantalum-wire-clip-with-septum-plug\"\u003ewire clip\u003c\/a\u003e). The working, counter and reference electrodes (all special autoclavable models) are mounted in a top casing either in 2-, or 3-electrode setup. The counter electrode is placed in a separate PEEK compartment separated from the other electrodes by a ceramic frit. The cell elements are constructed with materials that are inert to the sample (PTFE and PEEK). The cell does not contain any O-Ring and the electrodes are fixed using PEEK screws. The construction of the cell and electrodes is open to equalize the pressure inside those components. After removal of the counter electrode PEEK compartment, the setup gets the functionality of a single-compartment cell. \u003cspan data-mce-fragment=\"1\"\u003eThe cell chamber is available in several material variants \u003c\/span\u003e\u003ca href=\"https:\/\/wholesale.redox.me\/collections\/accessories\/products\/50-ml-cell-chamber\" title=\"cell chamber\" data-mce-fragment=\"1\" target=\"_blank\" data-mce-href=\"https:\/\/wholesale.redox.me\/collections\/accessories\/products\/50-ml-cell-chamber\"\u003ehere\u003c\/a\u003e\u003cspan data-mce-fragment=\"1\"\u003e.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication note:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eThe cell is intended to be used inside an autoclave or a digestion bomb under a hydrothermal conditions. Such device should allow installation of the electrical connections to the electrodes without the risk of decompression. The cell installation inside the autoclave must be done in accordance with the safety rules. Various electrodes are suitable for this cell including metal wire and metal foil electrodes as well as graphite rod. However, the electrode has to be autoclave-safe (not containing glue, regular glass, corroding metals, low melting point plastics).\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecification:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003emaxi\u003cspan data-mce-fragment=\"1\"\u003emum electrolyte volume: 50 mL\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eelectrode plug diameter: 6 mm\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003enumber of electrode slots: 3\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCell includes:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e1 x lid\u003cbr data-mce-fragment=\"1\"\u003e1 x PEEK chamber\u003cbr data-mce-fragment=\"1\"\u003e1 x CE PEEK compartment\u003cbr data-mce-fragment=\"1\"\u003e1 x set of screws\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eIntrastat data:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eHS Code: 90309000\u003cbr data-mce-fragment=\"1\"\u003eCountry of Origin: Sweden\u003cbr data-mce-fragment=\"1\"\u003eNET weight: 200 g\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSetup includes:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e1 x Autoclavable Two-compartment Electrochemical Cell - Autoclavable 2-CEC 50 mL,\u003cbr data-mce-fragment=\"1\"\u003e1 x Autoclavable Ag\/AgCl Reference Electrode\u003cbr data-mce-fragment=\"1\"\u003e1 x Autoclavable version of Metal Wire Auxiliary Electrode - 50HX15 0.6\/250 mm (Gold)\u003cbr data-mce-fragment=\"1\"\u003e1 x Autoclavable version of disk electrode – Glassy carbon\u003cbr data-mce-fragment=\"1\"\u003e1 x Plug with silicone rubber septum and set of Tantalum wire clips (set of 10)\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Redoxme","offers":[{"title":"Default Title","offer_id":43364950376629,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/Autoclavable2-CEC_540x_245498a4-77dc-4f93-84f7-3a46f5420c5f.png?v=1701304995"},{"product_id":"basic-electrochemical-h-cell-setup","title":"BASIC ELECTROCHEMICAL H-CELL SETUP","description":"\u003cdiv class=\"product-description rte\" data-mce-fragment=\"1\" itemprop=\"description\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis is a stationary solution double compartment electrochemical H-Cell for measurements of electrodes in a form of: a) rod\/disc (6 mm dia.), b) thin film deposited on a flat substrate (using a wire clip) and c) membrane (using a wire clip). The working, counter and reference electrodes are mounted in a top casing either in 2-, or 3-electrode setup.\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe counter electrode is placed in a compartment separated from the other electrodes by \u003c\/span\u003eion-exchange membrane\u003cspan data-mce-fragment=\"1\"\u003e (19 mm to 25 mm dia.), \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eso the electrochemical products appearing at working and counter electrode do not affect the opposite electrode\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e. The counter electrode compartment is equipped with a separate inlet and outlet for easy filling with an electrolyte and evacuation of gaseous products. It can accommodate standard \u003c\/span\u003eMetal Wire Auxiliary Electrode\u003cspan data-mce-fragment=\"1\"\u003e as well as \u003c\/span\u003esquare shape\u003cspan data-mce-fragment=\"1\"\u003e electrodes with sizes up to \u003c\/span\u003e25 mm x 25 mm\u003cspan data-mce-fragment=\"1\"\u003e.\u003c\/span\u003e The cell elements are constructed with materials that are inert to the sample (glass and PEEK). It well fits aqueous (FKM\/EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight and can be used when the removal and exclusion of contaminants such as oxygen and water is required by bubbling of an inert gas through the electrolyte. After removal of the counter electrode glass compartment, the cell gets the functionality of a\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/wholesale.redox.me\/collections\/electrochemical-cell-setups\/products\/basic-electrochemical-cell-setup\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/wholesale.redox.me\/collections\/electrochemical-cell-setups\/products\/basic-electrochemical-cell-setup\" target=\"_blank\"\u003eBasic Electrochemical Cell – BEC 50 mL\u003c\/a\u003e. \u003cspan data-mce-fragment=\"1\"\u003eThe cell chamber is available in several material variants \u003c\/span\u003e\u003ca title=\"cell chamber\" href=\"https:\/\/wholesale.redox.me\/collections\/accessories\/products\/50-ml-cell-chamber\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/wholesale.redox.me\/collections\/accessories\/products\/50-ml-cell-chamber\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003cspan data-mce-fragment=\"1\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication note:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eThe reference electrode tip and working disk electrode tip should be placed in the middle of the membrane. This will ensure a low potential drop throughout the electrolyte solution for low-current experiment. \u003cspan data-mce-fragment=\"1\"\u003eVarious auxiliary electrodes are suitable for this cell including \u003c\/span\u003emetal wire\u003cspan data-mce-fragment=\"1\"\u003e and \u003c\/span\u003emetal foil\/mesh\/foam\u003cspan data-mce-fragment=\"1\"\u003e electrodes as well as \u003c\/span\u003egraphite rod\u003cspan data-mce-fragment=\"1\"\u003e. The bubbling of gas through the solution must be stopped prior to experiment. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecification:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eminimum electrolyte volume in WE compartment: 22 mL\u003cbr data-mce-fragment=\"1\"\u003eminimum electrolyte volume in CE compartment: 6 mL\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003emaximum electrolyte volume: 40 mL\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eminimum membrane diameter: 19 mm\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003emaximum membrane diameter: 25 mm\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003emaximum membrane thickness: 0.5 mm\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003eelectrode plug diameter: 6 mm\u003cbr data-mce-fragment=\"1\"\u003enumber of electrode slots: 3\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eIntrastat data:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eHS Code: 90309000\u003cbr data-mce-fragment=\"1\"\u003eCountry of Origin: Sweden\u003cbr data-mce-fragment=\"1\"\u003eNET weight: 200 g\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSetup includes:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e1 x BE H-Cell 50 mL - Basic Electrochemical H-Cell 50 mL\u003cbr data-mce-fragment=\"1\"\u003e1 x Metal Wire Auxiliary Electrode - 50HX15 0.6\/250 mm (Platinum)\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e1 x Reference electrode (Ag\/AgCl, or Ag\/Ag+)\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e1 x Glassy Carbon disk electrode – 2 mm dia.\u003cbr data-mce-fragment=\"1\"\u003e1 x Plug with silicone rubber septum and set of Tantalum wire clips (set of 10)\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Redoxme","offers":[{"title":"Aqueous electrolyte experiment","offer_id":43364954931381,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment","offer_id":43364954964149,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/BEH-cell50mL_540x_061b511b-039a-4414-bacd-afebc5b40631.png?v=1701305286"},{"product_id":"bottom-mount-electrochemical-cell-setup","title":"BOTTOM MOUNT ELECTROCHEMICAL CELL SETUP","description":"\u003cdiv class=\"product-description rte\" data-mce-fragment=\"1\" itemprop=\"description\"\u003e\n\u003cp\u003eThis is a stationary solution voltammetry cell for measurements of a thin film deposited on flat substrate. The sample is loaded from the bottom via magnetic (or screw) mount, while \u003cspan\u003ecounter or\/and reference electrodes are mounted in a top casing (either 2-, or 3-electrode setup). The cell elements are constructed with materials that are inert to the sample (glass and PEEK). It well fits aqueous (FKM\/EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight and can be used when the removal and exclusion of contaminants such as oxygen and water is required by bubbling of an inert gas through the electrolyte. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eApplication note:\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003eThe \u003cspan\u003ereference electrode tip should be placed close to the bottom of the chamber (3-5 mm), where the working electrode is exposed to the electrolyte. This will ensure a negligible potential drop throughout the electrolyte solution for low-current experiment. Various auxiliary electrodes are suitable for this cell including metal wire and metal foil electrodes as well as graphite rod. The bubbling of gas through the solution must be stopped prior to experiment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003enominal exposure area: 1 cm\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e\u003cbr\u003eminimum electrolyte volume: 2.5 mL\u003cbr\u003emaximum electrolyte volume: 15 mL\u003cbr\u003eelectrode plug diameter: 6 mm\u003cbr\u003eminimum substrate size: 17 mm x 25 mm\u003cbr\u003erecommended substrate size: 25 mm x 25 mm\u003cbr\u003emaximum substrate thickness: 3 mm\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntrastat data:\u003c\/strong\u003e\u003cbr\u003eHS Code: 90309000\u003cbr\u003eCountry of Origin: Sweden\u003cbr\u003eNET weight: 200 g\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSetup includes:\u003cbr\u003e\u003c\/strong\u003e\u003cspan\u003e1 x Bottom Magnetic Mount Electrochemical Cell – BMM EC 15 mL\u003c\/span\u003e\u003cspan\u003e (or Bottom Mount Electrochemical Cell – BM EC 15 mL)\u003cbr\u003e\u003c\/span\u003e1 x Metal Wire Auxiliary Electrode - 50HX15 0.6\/250 mm (Platinum)\u003cbr\u003e\u003cspan data-mce-fragment=\"1\"\u003e1 x Reference electrode (Ag\/AgCl, or Ag\/Ag+)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Redoxme","offers":[{"title":"Aqueous electrolyte experiment","offer_id":43364955619509,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment","offer_id":43364955652277,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/3_540x_2f503a0d-2b92-4f0f-976c-2cf19fc2a51e.png?v=1701305442"},{"product_id":"bottom-mount-corrosion-cell-setup","title":"BOTTOM MOUNT CORROSION CELL SETUP","description":"\u003cdiv class=\"product-description rte\" data-mce-fragment=\"1\" itemprop=\"description\"\u003e\n\u003cdiv class=\"product-description rte\" itemprop=\"description\"\u003e\n\u003cp\u003eThis is a stationary solution corrosion cell for EIS and conventional electrochemical measurements on: (a) thin metal film deposited on flat substrate, (b) metal plate, (c) metal mesh, (d) metal wire and (e) metal ribbon. The sample is installed from the bottom via magnetic (or screw) mount in between two chambers filled with electrolyte. In cases (a) and (b) bottom chamber is unused and stays dry. The counter or\/and reference electrodes are mounted in a top casing (either 2-, or 3-electrode setup). The cell elements are constructed with materials that are inert to the sample (glass and PEEK). It well fits aqueous (\u003cspan\u003eFKM\/EPDM \u003c\/span\u003eO-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight and can be used when the removal and exclusion of contaminants such as oxygen and water is required by bubbling of an inert gas through the electrolyte.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication note:\u003c\/strong\u003e\u003cbr\u003eThe reference electrode tip should be placed close to the bottom of the chamber (3-5 mm), where the working electrode is exposed to the electrolyte. This will ensure a negligible potential drop throughout the electrolyte solution for low-current experiment. Various auxiliary electrodes are suitable for this cell including noble metal wire and graphite rod. The bubbling of gas through the solution must be stopped prior to experiment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003cbr\u003enominal exposure area: 1 cm2\u003cbr\u003eminimum electrolyte volume: 2.5 mL\u003cbr\u003emaximum electrolyte volume: 15 mL\u003cbr\u003eelectrode plug diameter: 6 mm\u003cbr\u003esample sizes:\u003cbr\u003ea) metal plate and thin metal film on a flat substrate:\u003cbr\u003eminimum sample size: 17 mm x 25 mm\u003cbr\u003erecommended sample size: 25 mm x 25 mm\u003cbr\u003emaximum sample thickness: 3 mm\u003cbr\u003eb) wire and ribbon:\u003cbr\u003emaximum sample thickness: 0.25 mm\u003cbr\u003eminimum sample length: 25 mm\u003cbr\u003e(higher thicknesses can be used with O-Ring grease)\u003cbr\u003ec) metal mesh:\u003cbr\u003emesh size: 80 - 500 wires\/inch\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntrastat data:\u003c\/strong\u003e\u003cbr\u003eHS Code: 90309000\u003cbr\u003eCountry of Origin: Sweden\u003cbr\u003eNET weight: 200 g\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSetup includes:\u003c\/strong\u003e\u003cbr\u003e1 x Bottom Magnetic Mount Corrosion Cell – BMM CC 15 mL (or Bottom Mount Corrosion Cell – BM CC 15 mL)\u003cbr\u003e1 x Metal Wire Auxiliary Electrode - 50HX15 0.6\/250 mm (Platinum)\u003cbr\u003e\u003cspan data-mce-fragment=\"1\"\u003e1 x Reference electrode (Ag\/AgCl, or Ag\/Ag+)\u003c\/span\u003e\u003cbr\u003e1 x Graphite rod electrode – GR 6\/70 mm\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Redoxme","offers":[{"title":"Aqueous electrolyte experiment","offer_id":43364958273717,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment","offer_id":43364958306485,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/BMMCORROSIONCELL_540x_59958fe0-47ee-4aef-b40e-5db35d86d60c.png?v=1701315343"},{"product_id":"flow-electrochemical-h-cell-setup","title":"FLOW ELECTROCHEMICAL H-CELL SETUP","description":"\u003cdiv class=\"product-description rte\" data-mce-fragment=\"1\" itemprop=\"description\"\u003e\n\u003cdiv class=\"product-description rte\" itemprop=\"description\"\u003e\n\u003cdiv class=\"product-description rte\" itemprop=\"description\"\u003e\n\u003cp\u003eThis is a horizontally mounted, double compartment electrochemical flow H-Cell. The cell elements are made of PEEK. It well fits aqueous (FKM\/EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight having two separate chambers, each equipped with electrolyte inlet and outlet. This allows filling up the cell with an electrolyte (static mode) or circulation of the electrolyte (flow mode). Chambers are separated with an\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/wholesale.redox.me\/collections\/membranes\/products\/nafion-membrane-20-mm-dia-pack-of-100\" target=\"_blank\"\u003eion-exchange membrane\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cem\u003ee.g.\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eDuPont’s Nafion® membrane), so the electrochemical products appearing at working and counter electrode do not affect the opposite electrode. Each chamber is able to accommodate three electrodes. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication note:\u003c\/strong\u003e\u003cbr\u003eThis cell allows several approaches to perform measurements in 2- or 3-electrode setups. It is designed to investigate the performance of a material (\u003cem\u003ee.g.\u003c\/em\u003e nanocrystalline material or conducting polymer) deposited on a\u003cspan\u003e \u003c\/span\u003e\u003ca title=\"disk electrode\" href=\"https:\/\/wholesale.redox.me\/collections\/electrodes\/products\/working-disk-electrode-2-mm-dia-peek-body\" target=\"_blank\"\u003eworking disk electrode\u003c\/a\u003e. The metal wire counter electrode is mounted in the second chamber, while the\u003cspan\u003e \u003c\/span\u003e\u003ca title=\"reference electrode\" href=\"https:\/\/redox.me\/collections\/reference-electrodes\" target=\"_blank\"\u003ereference electrode\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eis mounted in the same chamber as the working electrode. Various counter electrodes are suitable for this cell including\u003cspan\u003e \u003c\/span\u003e\u003ca title=\"metal wire counter electrode\" href=\"https:\/\/redox.me\/collections\/metal-wire-auxiliary-electrodes\" target=\"_blank\"\u003emetal wire\u003c\/a\u003e, as well as non-metal electrodes such as\u003cspan\u003e \u003c\/span\u003e\u003ca title=\"graphite rod counter electrode\" href=\"https:\/\/wholesale.redox.me\/collections\/electrodes\/products\/graphite-rod-electrode-gr-6-70-mm\" target=\"_blank\"\u003egraphite rod\u003c\/a\u003e. Typical applications include: basic electrochemistry, long-term measurements, RE potential measurements as well as electrosynthesis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003cbr\u003enominal exposure area of an ion-exchange membrane: 1 cm\u003csup\u003e2\u003c\/sup\u003e\u003cbr\u003eminimum electrolyte volume: 2x1 mL\u003cbr\u003emaximum electrolyte volume: 2x1.5 mL\u003cbr\u003eelectrode plug diameter: 6 mm\u003cbr\u003emaximum ion-exchange membrane thickness: 3 mm\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntrastat data:\u003c\/strong\u003e\u003cbr\u003eHS Code: 90309000\u003cbr\u003eCountry of Origin: Sweden\u003cbr\u003eNET weight: 200 g\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSetup includes:\u003c\/strong\u003e\u003cbr\u003e1 x Flow Electrochemical Cell - FEC H-CELL 2x1.5mL,\u003cbr\u003e1 x Metal Wire Auxiliary Electrode - 50HX15 0.6\/250 mm (Platinum 99,9%),\u003cbr\u003e1 x Reference electrode (Ag\/AgCl, or Ag\/Ag+),\u003cbr\u003e1 x Glassy Carbon disk electrode – 2 mm dia.\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Redoxme","offers":[{"title":"Aqueous electrolyte experiment","offer_id":43364961255605,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment","offer_id":43364961288373,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/5_1024x1024_540x_5b79464e-1ac9-4106-92b1-db45e856df9d.png?v=1701305844"},{"product_id":"electrochemical-quartz-crystal-microbalance-cell-setup","title":"ELECTROCHEMICAL QUARTZ CRYSTAL MICROBALANCE CELL SETUP","description":"\u003cdiv class=\"product-description rte\" data-mce-fragment=\"1\" itemprop=\"description\"\u003e\n\u003cdiv class=\"product-description rte\" itemprop=\"description\"\u003e\n\u003cdiv class=\"product-description rte\" itemprop=\"description\"\u003e\n\u003cp\u003eThis is a stationary solution voltammetry cell for simultaneous measurements of electrochemical response and Quartz Crystal Microbalance sensing. It is a universal EQCM cell that works with both standard sizes of quartz sensors, either 14 mm or 25.4 mm in diameter. In this configuration, a thin film or measured material is deposited directly onto upper electrode of a QCM sensor. The counter and reference electrodes are mounted in a top casing (either 2-, or 3-electrode setup). The cell elements are constructed with materials that are inert to the sample (glass and PEEK). It well fits aqueous (\u003cspan\u003eFKM\/EPDM \u003c\/span\u003eO-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight and can be used when the removal and exclusion of contaminants such as oxygen and water is required by bubbling of an inert gas through the electrolyte.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication note:\u003c\/strong\u003e\u003cbr\u003eThe reference electrode tip should be placed close to the QCM sensor upper electrode (3-5 mm), where the working electrode is exposed to the electrolyte. This will ensure a negligible potential drop throughout the electrolyte solution for low-current experiment. Various auxiliary electrodes are suitable for this cell including\u003cspan\u003e \u003c\/span\u003emetal wire\u003cspan\u003e \u003c\/span\u003eand metal foil electrodes as well as\u003cspan\u003e \u003c\/span\u003egraphite rod. The bubbling of gas through the solution must be stopped prior to experiment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003cbr\u003ecompatibility: standard QCM sensor with 14 mm or 25.4 mm dia.\u003cbr\u003eminimum electrolyte volume: 2.5 mL\u003cbr\u003emaximum electrolyte volume: 15 mL\u003cbr\u003eelectrode plug diameter: 6 mm\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntrastat data:\u003c\/strong\u003e\u003cbr\u003eHS Code: 90160090\u003cbr\u003eCountry of Origin: Sweden\u003cbr\u003eNET weight: 200 g\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSetup includes:\u003c\/strong\u003e\u003cbr\u003e1 x Magnetic Mount Electrochemical Quartz Crystal Microbalance Cell (or Electrochemical Quartz Crystal Microbalance Cell)\u003cbr\u003e1 x Metal Wire Auxiliary Electrode - 50HX15 0.6\/250 mm (Platinum 99,9%)\u003cbr\u003e1 x Reference electrode (Ag\/AgCl, or Ag\/Ag+), 70 mm\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Redoxme","offers":[{"title":"Aqueous electrolyte experiment \/ Magnetic mount \/ 14 mm dia.","offer_id":43364964073653,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Aqueous electrolyte experiment \/ Magnetic mount \/ 25.4 mm dia.","offer_id":43364965843125,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Aqueous electrolyte experiment \/ Screw mount \/ 14 mm dia.","offer_id":43364965875893,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Aqueous electrolyte experiment \/ Screw mount \/ 25.4 mm dia.","offer_id":43364965908661,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment \/ Magnetic mount \/ 14 mm dia.","offer_id":43364964106421,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment \/ Magnetic mount \/ 25.4 mm dia.","offer_id":43364965941429,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment \/ Screw mount \/ 14 mm dia.","offer_id":43364965974197,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment \/ Screw mount \/ 25.4 mm dia.","offer_id":43364966006965,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/EQCM14mmor254mmdia_540x_6350eb02-0fe0-45cc-b093-8ca91ec631ea.png?v=1701315185"},{"product_id":"front-contact-photo-electrochemical-single-sided-cell-setup","title":"FRONT CONTACT PHOTO-ELECTROCHEMICAL SINGLE-SIDED CELL SETUP","description":"\u003cdiv class=\"product-description rte\" data-mce-fragment=\"1\" itemprop=\"description\"\u003e\n\u003cdiv class=\"product-description rte\" itemprop=\"description\"\u003e\n\u003cdiv class=\"product-description rte\" itemprop=\"description\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis is a horizontally mounted, single compartment photo-electrochemical cell. This cell allows several approaches to perform measurements in 2- or 3-electrode setups. It is designed to investigate performance of a thin film photo-anode (\u003cem data-mce-fragment=\"1\"\u003ee.g.\u003c\/em\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003enanocrystalline material or conducting polymer) deposited on a rigid or flexible transparent substrate (typically FTO coated or uncoated borosilicate or fused quartz glass). The electrical connection to the photo-anode is provided by a Copper foil contact facing the sample from the front (\u003cem data-mce-fragment=\"1\"\u003ei.e.\u003c\/em\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003etouching the photo active film). The Copper contact stays dry during the experiment as it is located out of the sample sealing O-Ring outer diameter. The cathode (counter electrode) and reference electrode are mounted in a lid. The cell elements are made of PEEK. It well fits aqueous (EPDM\/FKM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight having gas inlet and outlet, which can be used to bubble the solution and evacuate gases from the chamber.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication note:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eA thin film of interest deposited on a transparent glass or plastic foil is installed in the magnetic or \u003cspan data-mce-fragment=\"1\"\u003ehook clamp assembled\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003emount, facing the cell chamber. In 2-electrode setup, the counter electrode is placed in the socket close to the working electrode while the remaining socket is plugged. When 3-electrode setup is required, the reference electrode is placed close to the measured sample to limit the effect of electrolyte resistance, while the counter electrode occupies the remaining socket. Various auxiliary electrodes are suitable for this cell including\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003emetal wire, gauze and foil electrodes\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eas well as\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003enon-metal electrodes. Typical applications include: basic photochemistry, photolytic water splitting, CO2 reduction, photoinduced charge separation and photocorrosion.\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003cbr\u003enominal exposure area:\u003cbr\u003e     0.2 cm\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e(customizable) - magnetic mount variant;\u003cbr\u003e     0.2 cm\u003csup\u003e2\u003c\/sup\u003e, or 1 cm\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e(customizable) - hook clamp assembled mount variant\u003cbr\u003eminimum electrolyte volume: 10 mL\u003cbr\u003emaximum electrolyte volume: 15 mL\u003cbr\u003eelectrode plug diameter: 6 mm\u003cbr\u003eminimum substrate size: 7 mm x 7 mm\u003cbr\u003emaximum substrate width: 36 mm\u003cbr\u003emaximum substrate thickness: 4 mm\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntrastat data:\u003c\/strong\u003e\u003cbr\u003eHS Code: 90309000\u003cbr\u003eCountry of Origin: Sweden\u003cbr\u003eNET weight: 300g\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCell includes:\u003cbr\u003e\u003c\/strong\u003e1 x lid –\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/redox.me\/products\/0001cpema-lid-2-ports-inlet-outlet?variant=21344695975996\" data-mce-href=\"https:\/\/redox.me\/products\/0001cpema-lid-2-ports-inlet-outlet?variant=21344695975996\" target=\"_blank\"\u003e0001CPEMA\u003c\/a\u003e\u003cbr\u003e1 x chamber\u003cbr\u003e1 x Copper contact\u003cbr\u003e1 x sample mount or sample mount with hook clamps\u003cbr\u003e1 x tripod –\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/redox.me\/products\/0031pssma-pillar?variant=21354338025532\" data-mce-href=\"https:\/\/redox.me\/products\/0031pssma-pillar?variant=21354338025532\" target=\"_blank\"\u003e0031PSSMA\u003c\/a\u003e\u003cbr\u003e1 x plug –\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/redox.me\/products\/0005cpema-plug?variant=21344844447804\" data-mce-href=\"https:\/\/redox.me\/products\/0005cpema-plug?variant=21344844447804\" target=\"_blank\"\u003e0005CPEMA\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSetup includes:\u003cbr\u003e\u003c\/strong\u003e1 x HCA FC PEC 15 mL single-sided - Hook Clamp Assembled Front Contact Photo-electrochemical Cell (or MM FC PEC 15 mL single-sided - Magnetic Mount Front Contact Photo-electrochemical Cell),\u003cbr\u003e1 x Metal Wire Auxiliary Electrode - 50HX15 0.6\/250 mm (Platinum),\u003cbr\u003e1 x Reference electrode (Ag\/AgCl, or Ag\/Ag+), 30mm\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Redoxme","offers":[{"title":"Aqueous electrolyte experiment \/ Magnetic mount \/ 0.2 cm2","offer_id":43364967415989,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Aqueous electrolyte experiment \/ Magnetic mount \/ 1 cm2","offer_id":43364967448757,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Aqueous electrolyte experiment \/ Hook clamp assembled mount \/ 0.2 cm2","offer_id":43364967481525,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Aqueous electrolyte experiment \/ Hook clamp assembled mount \/ 1 cm2","offer_id":43364967514293,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment \/ Magnetic mount \/ 0.2 cm2","offer_id":43364967547061,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment \/ Magnetic mount \/ 1 cm2","offer_id":43364967579829,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment \/ Hook clamp assembled mount \/ 0.2 cm2","offer_id":43364967612597,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment \/ Hook clamp assembled mount \/ 1 cm2","offer_id":43364967645365,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/MMFCPEC15mLsetup_540x_2add8df8-72a1-47ed-ba56-b7e9f88b48cc.png?v=1701307731"},{"product_id":"gas-diffusion-electrode-x-ray-diffraction-electrochemical-cell-setup","title":"GAS DIFFUSION ELECTRODE X-RAY DIFFRACTION ELECTROCHEMICAL CELL SETUP","description":"\u003cdiv class=\"product-description rte\" data-mce-fragment=\"1\" itemprop=\"description\"\u003e\n\u003cdiv class=\"product-description rte\" itemprop=\"description\"\u003e\n\u003cdiv class=\"product-description rte\" itemprop=\"description\"\u003e\n\u003cp\u003eThis is a horizontally mounted, multi-purpose electrochemical cell for Gas Diffusion Electrode (GDE), designed to be used with X-Ray Diffractometry. The cell consists of two individual compartments: the liquid flow chamber and the gas chamber, which are placed on opposing faces of a GDE. Both compartments are held in place by magnetic\/screw mount, providing a leakage-free O-Ring seal. The liquid chamber can be filled with an electrolyte using a syringe or an electrolyte can continuously flow through it using an external reservoir and peristaltic pump (both not included). The dry chamber is gas-tight enabling continuous flow of a gas carrier and evacuation of the gas products for sampling using standard analytical instruments such as a residual gas analyzer. Both compartments are made of a polyether ether ketone (PEEK) material. The cell is meant to be used with standard reference electrode having 6 mm in diameter and counter electrode in the form of a rod\/helix with 6 mm in diameter and 15 mm active.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication note:\u003c\/strong\u003e\u003cbr\u003eGDE XRD Electrochemical Cell is used to effectively screen and validate GDEs for metal-air batteries, water electrolyzes, and alkaline fuel cells. It also enables in-situ X-Ray Diffraction acquisition. It is used as an air-breathing, thermodynamically referenced electroanalytical cell that allows to mimic the Janus arrangement of the GDE in a metal–air cell: one face freely exposed to gases, the other wetted by electrolyte.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003cbr\u003enominal exposure area: 1 cm2\u003cbr\u003eelectrolyte thickness: 12 mm\u003cbr\u003eliquid flow chamber volume: 1.75 mL\u003cbr\u003emaximum GDE thickness: 4 mm\u003cbr\u003eminimum GDE size: 17 mm x 25 mm\u003cbr\u003erecommended GDE size: 25 mm x 25 mm\u003cbr\u003eelectrode plug diameter: 6 mm\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntrastat data:\u003c\/strong\u003e\u003cbr\u003eHS Code: 90275000\u003cbr\u003eCountry of Origin: Sweden\u003cbr\u003eNET weight: 300 g\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSetup includes:\u003c\/strong\u003e\u003cbr\u003e1 x Magnetic Mount Gas Diffusion Electrode X-Ray Diffraction Electrochemical Cell – MM GDE XRD EC 1.75 mL (or Gas Diffusion Electrode X-Ray Diffraction Electrochemical Cell – GDE XRD EC 1.75 mL)\u003cbr\u003e1 x Metal Wire Auxiliary Electrode - 35HX15 0.6\/235 mm (Platinum)\u003cbr\u003e\u003cspan data-mce-fragment=\"1\"\u003e1 x Reference electrode (Ag\/AgCl, or Ag\/Ag+)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Redoxme","offers":[{"title":"Aqueous electrolyte experiment \/ Magnetic mount","offer_id":43364970168501,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Aqueous electrolyte experiment \/ Screw mount","offer_id":43364970234037,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment \/ Magnetic mount","offer_id":43364970299573,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment \/ Screw mount","offer_id":43364970365109,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/3_540x_b09d99a9-05c1-42a6-86ef-c83395cd6bea.png?v=1701306918"},{"product_id":"spectro-electrochemical-flow-cell-setup","title":"SPECTRO-ELECTROCHEMICAL FLOW CELL SETUP","description":"\u003cdiv class=\"product-description rte\" data-mce-fragment=\"1\" itemprop=\"description\"\u003e\n\u003cdiv class=\"product-description rte\" itemprop=\"description\"\u003e\n\u003cdiv class=\"product-description rte\" itemprop=\"description\"\u003e\n\u003cp\u003eThis is a horizontally mounted, multi-purpose spectroelectrochemical cell designed to be used with standard UV-Vis or IR spectrometers. It enables obtaining electrochemical and spectroscopic information from liquid sample or thin films in systems where variations in applied potential induce changes in observed spectra. It consists of a polyether ether ketone (PEEK) flow chamber equipped with a magnetic or screw mount sample holder, screw mount quartz window holder and two different mini tripods. It well fits aqueous (FKM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The cell is meant to be used with a standard reference electrode having 6 mm in diameter and a counter electrode either in the form of a rod or helix with 6 mm in diameter and 15 mm active length.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication note:\u003c\/strong\u003e\u003cbr\u003eThe spectroelectrochemical cell is used to study the relation between absorbance\/transmittance and electrochemical potential. It enables real-time monitoring of optical change in electrochromic materials. It also enables in-situ spectral acquisition for detection, identification and characterization of short-lived electrochemically-generated species\/intermediates, resulting in a detailed investigation of the mechanistic pathways of redox processes.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003cbr\u003enominal exposure area: 1 cm\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e(other values on request)\u003cbr\u003eoptical path length (electrolyte thickness): 12 mm\u003cbr\u003eflow chamber volume: 1.75 mL\u003cbr\u003emaximum substrate thickness: 4 mm\u003cbr\u003eelectrode plug diameter: 6 mm\u003cbr\u003eminimum substrate size: 17 mm x 25 mm\u003cbr\u003erecommended substrate size: 25 mm x 25 mm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntrastat data:\u003c\/strong\u003e\u003cbr\u003eHS Code: 90275000\u003cbr\u003eCountry of Origin: Sweden\u003cbr\u003eNET weight: 300 g\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSetup includes:\u003cbr\u003e\u003c\/strong\u003e1 x Magnetic Mount Spectro-Electrochemical Flow Cell – MM spectro-EFC 1.75 mL (or Spectro-Electrochemical Flow Cell – spectro-EFC 1.75 mL)\u003cbr\u003e1 x Metal Wire Auxiliary Electrode - 35HX15 0.6\/235 mm (Platinum)\u003cbr\u003e\u003cspan data-mce-fragment=\"1\"\u003e1 x Reference electrode (Ag\/AgCl, or Ag\/Ag+)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Redoxme","offers":[{"title":"Aqueous electrolyte experiment \/ Magnetic mount","offer_id":43365326258357,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Aqueous electrolyte experiment \/ Screw mount","offer_id":43365326291125,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment \/ Magnetic mount","offer_id":43365326323893,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment \/ Screw mount","offer_id":43365326356661,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/Spectro-EFC175_540x_2e6a6bbb-885e-4d09-9fa4-ee120cd0b416.png?v=1701325680"},{"product_id":"electrosynthesis-reactor-a-series-30-mm-od-5-port","title":"ELECTROSYNTHESIS REACTOR A-SERIES, 30 MM OD, 5-PORT","description":"\u003cdiv class=\"product-description rte\" data-mce-fragment=\"1\" itemprop=\"description\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eElectrosynthesis Reactor A-series is an undivided batch cell that contains a solution of the substrates and reagents and it is operating for the time needed to complete the desired reaction until all the starting material is consumed. The reaction mixture can be stirred using a magnetic stirrer to have a homogeneous concentration throughout the cell.\u003cbr data-mce-fragment=\"1\"\u003eIn this reactor, a solid anode (positive) and cathode (negative) are installed in\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca title=\"Tantalum clips\" href=\"https:\/\/wholesale.redox.me\/collections\/working-electrodes-current-collectors\/products\/tantalum-wire-clip-with-septum-plug-10-pcs\" target=\"_blank\"\u003eTantalum clips\u003c\/a\u003e. If 3-electrode setup is required, the reference electrode is mounted in the reactor lid. Such electrode assembly is introduced into a solution containing the substrate and a supporting electrolyte, in order to carry the current through the cell.\u003cbr data-mce-fragment=\"1\"\u003eThe reactor can be heated up or cooled down according to the requirements of the reaction.\u003cbr data-mce-fragment=\"1\"\u003eThe reactor elements are constructed with materials that are inert to most of the aqueous\/organic reaction environments (glass, PEEK, PTFE tubing, EPDM\/FFKM O-Rings). The construction of this reactor is liquid- and gas-tight.\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication note:\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003eThis electrosynthesis reactor is suitable for both, constant current and constant potential electrolysis in aqueous or organic media. As this is an undivided cell, it can be used when the substrate and product formed cannot react at the counter electrode, or with the products produced as a counter reaction.\u003cbr data-mce-fragment=\"1\"\u003eVarious anode materials are suitable for this reactor including: (i)\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca title=\"gold and platinum electrodes\" href=\"https:\/\/wholesale.redox.me\/products\/noble-metal-plate-platinum-gold-palladium?_pos=1\u0026amp;_sid=45c0ed0f2\u0026amp;_ss=r\" target=\"_blank\"\u003enoble metals such as platinum, platinum metals or their alloys, and gold\u003c\/a\u003e, (ii) carbon allotropes such as\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca title=\"graphite electrode\" href=\"https:\/\/wholesale.redox.me\/collections\/non-metal-electrodes\/products\/graphite-rod-electrode-gr-6-70-mm\" target=\"_blank\"\u003egraphite\u003c\/a\u003e,\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca title=\"reticulated glassy carbon\" href=\"https:\/\/wholesale.redox.me\/products\/reticulated-glassy-vitreous-carbon-electrode-od-30-mm-id-20-mm-h-25-mm-pt-wire-0-6-60-mm?_pos=2\u0026amp;_sid=5bb55ddd9\u0026amp;_ss=r\" target=\"_blank\"\u003ereticulated vitreous carbon\u003c\/a\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eor\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca title=\"glassy carbon\" href=\"https:\/\/wholesale.redox.me\/products\/glassy-vitreous-carbon-substrate-25-mm-x-25-mm?_pos=2\u0026amp;_sid=c62f8556d\u0026amp;_ss=r\" target=\"_blank\"\u003eglassy carbon\u003c\/a\u003e, (iii)\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca title=\"boron doped diamond\" href=\"https:\/\/wholesale.redox.me\/products\/boron-doped-diamond-plate?_pos=1\u0026amp;_sid=eb6283539\u0026amp;_ss=r\" target=\"_blank\"\u003eBoron-Doped Diamond plate\u003c\/a\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eand thin film on a substrate, and (iv) other metals such as nickel, lead or lead oxide.\u003cbr data-mce-fragment=\"1\"\u003eAs the corrosive effects are not common in cathode materials, there is a wider variety of materials to choose including: (i)\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca title=\"boron doped diamond\" href=\"https:\/\/wholesale.redox.me\/products\/boron-doped-diamond-plate?_pos=1\u0026amp;_sid=eb6283539\u0026amp;_ss=r\" target=\"_blank\"\u003eBoron-Doped Diamond plate\u003c\/a\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eand thin film on a substrate, (ii)\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca title=\"platinum plate\" href=\"https:\/\/wholesale.redox.me\/products\/noble-metal-plate-platinum-gold-palladium?_pos=1\u0026amp;_sid=45c0ed0f2\u0026amp;_ss=r\" target=\"_blank\"\u003eplatinum plate\u003c\/a\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eor\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/wholesale.redox.me\/products\/pt-and-au-wire-0-6-mm-dia-10-mm-length-unit?_pos=8\u0026amp;_sid=5b798136e\u0026amp;_ss=r\" target=\"_blank\"\u003ewire\u003c\/a\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eand (iii) other metals such as copper, nickel,\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca title=\"current collector\" href=\"https:\/\/wholesale.redox.me\/products\/current-collector-stainless-steel-316l-mesh-with-tantalum-clip-and-septum-plug?_pos=17\u0026amp;_sid=5b798136e\u0026amp;_ss=r\" target=\"_blank\"\u003estainless steel\u003c\/a\u003e, lead and tin.\u003cbr data-mce-fragment=\"1\"\u003eConcerning the form of the anode and the cathode, the materials with high surface-area-to-volume ratio are preferential. Copper and nickel are usually used in a form of a foam, while the other metals are in a form of plates, meshes and wires.\u003cbr data-mce-fragment=\"1\"\u003eTypical reference electrodes include\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca title=\"Ag\/Ag+\" href=\"https:\/\/wholesale.redox.me\/collections\/reference-electrodes\/products\/non-aqueous-silver-silver-ion-reference-electrode\" target=\"_blank\"\u003eAg\/Ag+ RE\u003c\/a\u003e (organic media),\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca title=\"Ag\/AgCl\" href=\"https:\/\/wholesale.redox.me\/collections\/reference-electrodes\/products\/silver-silver-chloride-refillable-reference-electrode-6-mm-dia\" target=\"_blank\"\u003eAg\/AgCl\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/a\u003e(aqueous media) and\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca title=\"pseudo reference electrode\" href=\"https:\/\/wholesale.redox.me\/products\/pseudo-reference-electrode-pr-0-6-50-mm?_pos=1\u0026amp;_sid=355c5dfec\u0026amp;_ss=r\" target=\"_blank\"\u003epseudo-RE (Pt, Au, Ag)\u003c\/a\u003e.\u003cbr data-mce-fragment=\"1\"\u003eNone of the above mentioned electrodes is included in the reactor, so they need to be added to the quotation separately. \u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecification:\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003emaximum electrolyte volume: 20 mL\u003cbr data-mce-fragment=\"1\"\u003eelectrode plug diameter: 6 mm\u003cbr data-mce-fragment=\"1\"\u003enumber of electrode slots: 5\u003cbr data-mce-fragment=\"1\"\u003edistance between anode and cathode: either 9 mm or 18 mm\u003cbr data-mce-fragment=\"1\"\u003eouter diameter of the glass chamber: 30 mm\u003cbr data-mce-fragment=\"1\"\u003eeffective height of the glass chamber: 41 mm\u003cbr data-mce-fragment=\"1\"\u003emaximum operational temperature: 200 deg C\u003cbr data-mce-fragment=\"1\"\u003eminimum operational temperature: -20 deg C\u003cbr data-mce-fragment=\"1\"\u003etubbing size: 1 mm ID, 1.6 mm OD\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntrastat data:\u003c\/strong\u003e\u003cbr\u003eHS Code: 90309000\u003cbr\u003eCountry of Origin: Sweden\u003cbr\u003eNET weight: 100 g\u003cbr\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003eProduct includes:\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e1 x lid\u003cbr data-mce-fragment=\"1\"\u003e1 x glass chamber\u003cbr data-mce-fragment=\"1\"\u003e3 x plug\u003cbr data-mce-fragment=\"1\"\u003e2 x plug with septum\u003cbr data-mce-fragment=\"1\"\u003e10 x Tantalum clips\u003cbr data-mce-fragment=\"1\"\u003e1 x set of O-Rings\u003cbr data-mce-fragment=\"1\"\u003e2 flangeless nuts for gas intel\/outlet (1\/16’’, 1.6 mm tubing)\u003cbr data-mce-fragment=\"1\"\u003e2 flangeless ferrules\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e(1\/16’’, 1.6 mm tubing)\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Redoxme","offers":[{"title":"Aqueous electrolyte experiment","offer_id":43365336383669,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment","offer_id":43365336416437,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/1_540x_dad2cfd8-d24b-4926-856a-2cec48cfc2c6.png?v=1701326304"},{"product_id":"electrosynthesis-reactor-a-series-septa-30-mm-od-5-port","title":"ELECTROSYNTHESIS REACTOR A-SERIES\/SEPTA, 30 MM OD, 5-PORT","description":"\u003cdiv class=\"product-description rte\" data-mce-fragment=\"1\" itemprop=\"description\"\u003e\n\u003cp\u003eElectrosynthesis Reactor A-series\/septa is an undivided batch cell that contains a solution of the substrates and reagents and it is operating for the time needed to complete the desired reaction until all the starting material is consumed. The reaction mixture can be stirred using a magnetic stirrer to have a homogeneous concentration throughout the cell.\u003cbr\u003eIn this reactor, a solid anode (positive) and cathode (negative) are installed in\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/wholesale.redox.me\/collections\/working-electrodes-current-collectors\/products\/tantalum-wire-clip-with-septum-plug-10-pcs\" target=\"_blank\"\u003eTantalum clips\u003c\/a\u003e. If 3-electrode setup is required, the reference electrode is mounted in the reactor lid. Such electrode assembly is introduced into a solution containing the substrate and a supporting electrolyte, in order to carry the current through the cell.\u003cbr\u003eThe reactor can be heated up or cooled down according to the requirements of the reaction.\u003cbr\u003eThe reactor elements are constructed with materials that are inert to most of the aqueous\/organic reaction environments (glass, PEEK, PTFE tubing, FKM\/FFKM O-Rings). The construction of this reactor is liquid- and gas-tight.\u003cbr\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication note:\u003cbr\u003e\u003c\/strong\u003eThis electrosynthesis reactor is suitable for both, constant current and constant potential electrolysis in aqueous or organic media. As this is an undivided cell, it can be used when the substrate and product formed cannot react at the counter electrode, or with the products produced as a counter reaction.\u003cbr\u003eVarious anode materials are suitable for this reactor including: (i)\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/wholesale.redox.me\/products\/noble-metal-plate-platinum-gold-palladium?_pos=1\u0026amp;_sid=45c0ed0f2\u0026amp;_ss=r\" target=\"_blank\"\u003enoble metals such as platinum, platinum metals or their alloys, and gold\u003c\/a\u003e, (ii) carbon allotropes such as\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/wholesale.redox.me\/collections\/non-metal-electrodes\/products\/graphite-rod-electrode-gr-6-70-mm\" target=\"_blank\"\u003egraphite\u003c\/a\u003e,\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/wholesale.redox.me\/products\/reticulated-glassy-vitreous-carbon-electrode-od-30-mm-id-20-mm-h-25-mm-pt-wire-0-6-60-mm?_pos=2\u0026amp;_sid=5bb55ddd9\u0026amp;_ss=r\" target=\"_blank\"\u003ereticulated vitreous carbon\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/wholesale.redox.me\/products\/glassy-vitreous-carbon-substrate-25-mm-x-25-mm?_pos=2\u0026amp;_sid=c62f8556d\u0026amp;_ss=r\" target=\"_blank\"\u003eglassy carbon\u003c\/a\u003e, (iii)\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/wholesale.redox.me\/products\/boron-doped-diamond-plate?_pos=1\u0026amp;_sid=eb6283539\u0026amp;_ss=r\" target=\"_blank\"\u003eBoron-Doped Diamond plate\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eand thin film on a substrate, and (iv) other metals such as nickel, lead or lead oxide.\u003cbr\u003eAs the corrosive effects are not common in cathode materials, there is a wider variety of materials to choose including: (i)\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/wholesale.redox.me\/products\/boron-doped-diamond-plate?_pos=1\u0026amp;_sid=eb6283539\u0026amp;_ss=r\" target=\"_blank\"\u003eBoron-Doped Diamond plate\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eand thin film on a substrate, (ii)\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/wholesale.redox.me\/products\/noble-metal-plate-platinum-gold-palladium?_pos=1\u0026amp;_sid=45c0ed0f2\u0026amp;_ss=r\" target=\"_blank\"\u003eplatinum plate\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/wholesale.redox.me\/products\/pt-and-au-wire-0-6-mm-dia-10-mm-length-unit?_pos=8\u0026amp;_sid=5b798136e\u0026amp;_ss=r\" target=\"_blank\"\u003ewire\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eand (iii) other metals such as copper, nickel,\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/wholesale.redox.me\/products\/current-collector-stainless-steel-316l-mesh-with-tantalum-clip-and-septum-plug?_pos=17\u0026amp;_sid=5b798136e\u0026amp;_ss=r\" target=\"_blank\"\u003estainless steel\u003c\/a\u003e, lead and tin.\u003cbr\u003eConcerning the form of the anode and the cathode, the materials with high surface-area-to-volume ratio are preferential. Copper and nickel are usually used in a form of a foam, while the other metals are in a form of plates, meshes and wires.\u003cbr\u003eTypical reference electrodes include\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/wholesale.redox.me\/collections\/reference-electrodes\/products\/non-aqueous-silver-silver-ion-reference-electrode\" target=\"_blank\"\u003eAg\/Ag+ RE\u003c\/a\u003e (organic media),\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/wholesale.redox.me\/collections\/reference-electrodes\/products\/silver-silver-chloride-refillable-reference-electrode-6-mm-dia\" target=\"_blank\"\u003eAg\/AgCl\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003e(aqueous media) and\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/wholesale.redox.me\/products\/pseudo-reference-electrode-pr-0-6-50-mm?_pos=1\u0026amp;_sid=355c5dfec\u0026amp;_ss=r\" target=\"_blank\"\u003epseudo-RE (Pt, Au, Ag)\u003c\/a\u003e.\u003cbr\u003eNone of the above mentioned electrodes is included in the reactor, so they need to be added to the quotation separately. For troubleshooting instruction see the \u003ca href=\"https:\/\/redox.me\/blogs\/good-measurement-practices\/troubleshooting-electrochemical-cell\" data-mce-href=\"https:\/\/redox.me\/blogs\/good-measurement-practices\/troubleshooting-electrochemical-cell\" data-mce-fragment=\"1\"\u003eredox.me blog post\u003c\/a\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecification:\u003cbr\u003e\u003c\/strong\u003emaximum electrolyte volume: 20 mL\u003cbr\u003eelectrode plug diameter: 6 mm\u003cbr\u003enumber of electrode slots: 5\u003cbr\u003edistance between anode and cathode: either 9 mm or 18 mm\u003cbr\u003eouter diameter of the glass chamber: 30 mm\u003cbr\u003eeffective height of the glass chamber: 41 mm\u003cbr\u003emaximum operational temperature: 200 deg C\u003cbr data-mce-fragment=\"1\"\u003eminimum operational temperature: -20 deg C\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003esepta size: ND9\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntrastat data:\u003c\/strong\u003e\u003cbr\u003eHS Code: 90309000\u003cbr\u003eCountry of Origin: Sweden\u003cbr\u003eNET weight: 100g\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eProduct includes:\u003cbr\u003e\u003c\/strong\u003e1 x lid\u003cbr\u003e1 x septa holder\u003cbr\u003e1 x glass chamber\u003cbr\u003e3 x plug\u003cbr\u003e2 x plug with septum\u003cbr\u003e10 x Tantalum clips\u003cbr\u003e1 x set of O-Rings\u003cbr\u003e1 x set of septum\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Redoxme","offers":[{"title":"Aqueous electrolyte experiment","offer_id":43365392974005,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment","offer_id":43365393006773,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/1_540x_d7ffefb5-0f36-44b6-b0f1-ad7d6a0456a0.png?v=1701329632"},{"product_id":"electrosynthesis-multiple-reactor-set-a-series","title":"ELECTROSYNTHESIS MULTIPLE REACTOR SET, A-SERIES","description":"\u003cdiv class=\"product-description rte\" data-mce-fragment=\"1\" itemprop=\"description\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan\u003eElectrosynthesis Multiple Reactor Set consists of a selected number of Electrosynthesis Reactors from \u003c\/span\u003e\u003ca href=\"https:\/\/wholesale.redox.me\/collections\/all\/products\/electrosynthesis-reactor-a-series-30-mm-od-5-port\" title=\"Electrosynthesis reactor\" target=\"_blank\"\u003eA-series\u003c\/a\u003e \u003cspan\u003eor \u003c\/span\u003e\u003ca href=\"https:\/\/wholesale.redox.me\/collections\/all\/products\/electrosynthesis-reactor-a-series-septa-30-mm-od-5-port\" title=\"Electrosynthesis reactor\"\u003eA-series\/septa\u003c\/a\u003e\u003cspan\u003e, and \u003c\/span\u003e\u003ca href=\"https:\/\/wholesale.redox.me\/products\/ptfe-coated-aluminum-block-a-series?_pos=1\u0026amp;_sid=1cf824112\u0026amp;_ss=r\" title=\"heating block\" target=\"_blank\"\u003ePTFE-coated Aluminum Block\u003c\/a\u003e\u003cspan\u003e with a corresponding number of cavities.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication note:\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003eThis Electrosynthesis Multiple Reactor Set is suitable for both, constant current and constant potential electrolysis in aqueous or organic media. The assembled set should be placed on a hot-plate or a hot-plate magnetic stirrer. The heating block has pre-drilled holes for a thermometer probe. Each of those holes is 120 mm deep and can accommodate probes with diameter of 2, 3, 4 and 5 mm. Electrodes are not\u003cspan data-mce-fragment=\"1\"\u003e included in the set, so they need to be added to the quotation separately.\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecification:\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003eweight: approx. 1.8 kg\u003cbr data-mce-fragment=\"1\"\u003emaximum electrolyte volume: 20 mL\/reactor\u003cbr data-mce-fragment=\"1\"\u003eelectrode plug diameter: 6 mm\u003cbr data-mce-fragment=\"1\"\u003enumber of electrode slots: 5\/reactor\u003cbr data-mce-fragment=\"1\"\u003edistance between anode and cathode: either 9 mm or 18 mm\u003cbr data-mce-fragment=\"1\"\u003eouter diameter of the reactor glass chamber: 30 mm\u003cbr data-mce-fragment=\"1\"\u003eeffective height of the reactor glass chamber: 41 mm\u003cbr data-mce-fragment=\"1\"\u003emaximum operational temperature: 200 deg C\u003cbr data-mce-fragment=\"1\"\u003eminimum operational temperature: -20 deg C\u003cbr data-mce-fragment=\"1\"\u003etubbing size (if any): 1 mm ID, 1.6 mm OD\u003cbr data-mce-fragment=\"1\"\u003esepta size (if any): ND9\u003cbr data-mce-fragment=\"1\"\u003eheating block height: 45 mm\u003cbr data-mce-fragment=\"1\"\u003eheating block cavity depth: 40 mm\u003cbr data-mce-fragment=\"1\"\u003eheating block cavity diameter: 31 mm\u003cbr data-mce-fragment=\"1\"\u003eheating block diameter: 135 mm\u003cbr data-mce-fragment=\"1\"\u003ethermometer hole diameter: 2.5 mm, 3.5 mm, 4.5 mm and 5.5 mm\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntrastat data:\u003c\/strong\u003e\u003cbr\u003eHS Code: 90309000\u003cbr\u003eCountry of Origin: Sweden\u003cbr\u003eNET weight: 1300 g (1 reactor), 1400 g (2 reactors), 1500 g (3 reactors), 1600 g (4 reactors), 1700 g (5 reactors), 1800 g (6 reactors)\u003cbr\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eProduct includes:\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e1 x PTFE-coated Aluminum Block A-series\u003cbr data-mce-fragment=\"1\"\u003eselected number of Electrosynthesis Reactors from A-series or A-series\/septa\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Redoxme","offers":[{"title":"Aqueous electrolyte experiment \/ 1 reactor \/ Tubing","offer_id":43365398970549,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Aqueous electrolyte experiment \/ 1 reactor \/ Septa","offer_id":43365403197621,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Aqueous electrolyte experiment \/ 2 reactors \/ Tubing","offer_id":43365403230389,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Aqueous electrolyte experiment \/ 2 reactors \/ Septa","offer_id":43365403263157,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Aqueous electrolyte experiment \/ 3 reactors \/ Tubing","offer_id":43365403295925,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Aqueous electrolyte experiment \/ 3 reactors \/ Septa","offer_id":43365403328693,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Aqueous electrolyte experiment \/ 4 reactors \/ Tubing","offer_id":43365403361461,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Aqueous electrolyte experiment \/ 4 reactors \/ Septa","offer_id":43365403394229,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Aqueous electrolyte experiment \/ 5 reactors \/ Tubing","offer_id":43365403426997,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Aqueous electrolyte experiment \/ 5 reactors \/ Septa","offer_id":43365403459765,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Aqueous electrolyte experiment \/ 6 reactors \/ Tubing","offer_id":43365403492533,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Aqueous electrolyte experiment \/ 6 reactors \/ Septa","offer_id":43365403525301,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment \/ 1 reactor \/ Tubing","offer_id":43365399003317,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment \/ 1 reactor \/ Septa","offer_id":43365403558069,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment \/ 2 reactors \/ Tubing","offer_id":43365403590837,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment \/ 2 reactors \/ Septa","offer_id":43365403623605,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment \/ 3 reactors \/ Tubing","offer_id":43365403656373,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment \/ 3 reactors \/ Septa","offer_id":43365403689141,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment \/ 4 reactors \/ Tubing","offer_id":43365403721909,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment \/ 4 reactors \/ Septa","offer_id":43365403754677,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment \/ 5 reactors \/ Tubing","offer_id":43365403787445,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment \/ 5 reactors \/ Septa","offer_id":43365403820213,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment \/ 6 reactors \/ Tubing","offer_id":43365403852981,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment \/ 6 reactors \/ Septa","offer_id":43365403885749,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/1_540x_f62356a9-ca3d-45dc-92b7-585e43be3e60.png?v=1701329934"},{"product_id":"immersible-electrosynthesis-reactor-h-cell-2x1-5-ml-15x15-mm2","title":"IMMERSIBLE ELECTROSYNTHESIS REACTOR, H-CELL, 2X1.5 ML, 15X15 MM2","description":"\u003cdiv class=\"product-description rte\" data-mce-fragment=\"1\" itemprop=\"description\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eIt is a two-compartment electrolytic flow cell designed specifically for electrosynthesis experiments. The whole cell can be immersed in a thermostatic bath to control the process temperature. Both chambers are made of Titanium which ensures proper heat exchange while providing chemical resistance for a broad range of chemicals. Thanks to the application of adjustable hook clamps, the reactor can be easily assembled and disassembled within seconds.  \u003cbr data-mce-fragment=\"1\"\u003eThe reactor\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003econsists mainly of the following elements: (i) Titanium anode chamber with intel\/outlet and additional electrode terminal (plugged when unused), (ii) Titanium cathode chamber with inlet\/outlet, and (iii) two electrode holders with a back electrode contact and a rod contact to the external circuit. Both electrodes (not included in the setup) are in a form of a flat plate with dimensions of 15 mm x 15 mm x 0.5 mm each (other sizes are available on request). Due to the back-contact connection between the current collector and the electrode, both electrodes should be made of a conductive material. Typically,\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/redox.me\/collections\/non-metal-auxiliary-electrodes\/products\/boron-doped-diamond-plate-bdd-plate\" title=\"Boron-Doped Diamond\" data-mce-href=\"https:\/\/redox.me\/collections\/non-metal-auxiliary-electrodes\/products\/boron-doped-diamond-plate-bdd-plate\" target=\"_blank\" data-mce-fragment=\"1\"\u003eBoron-Doped Diamond\u003c\/a\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eplate is used as an anode while Zirconium plate is used as a cathode. Other electrodes configurations include:\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/redox.me\/collections\/non-metal-auxiliary-electrodes\/products\/glassy-vitreous-carbon-substrates-gc-25-25-custom\" title=\"Glassy Carbon Plate\" data-mce-href=\"https:\/\/redox.me\/collections\/non-metal-auxiliary-electrodes\/products\/glassy-vitreous-carbon-substrates-gc-25-25-custom\" target=\"_blank\" data-mce-fragment=\"1\"\u003eGlassy Carbon Plates\u003c\/a\u003e,\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/redox.me\/collections\/working-electrodes-current-collectors\/products\/noble-metal-plate-platinum-gold-palladium\" title=\"Noble metal plate\" data-mce-href=\"https:\/\/redox.me\/collections\/working-electrodes-current-collectors\/products\/noble-metal-plate-platinum-gold-palladium\" target=\"_blank\" data-mce-fragment=\"1\"\u003eNobel Metal Plates (Platinum, Gold, Palladium and Silver)\u003c\/a\u003e, and other metal plates (Stainless Steel 316L\/317L, Nickel, Titanium, etc.). The\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/redox.me\/collections\/membranes\" title=\"membranes for electrosynthesis\" data-mce-href=\"https:\/\/redox.me\/collections\/membranes\" target=\"_blank\" data-mce-fragment=\"1\"\u003emembrane\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/a\u003eis circular with a diameter in a range of 20 to 25 mm, and thickness up to 1 mm.\u003cbr data-mce-fragment=\"1\"\u003eDuring the electrosynthesis process, the liquid electrolyte is circulated from the external thermoregulated reservoirs through both compartments separately. When the flow rate is sufficient, the flux hits the chamber wall and spreads evenly in the whole chamber volume providing proper mixing. The reacted liquid is then evacuated through the outlet located on the top of the chamber. In some cases, the reactor may also operate in a stagnant mode. The reactor elements that are in contact with the synthesized products are made of Titanium Grade 7. The seal is provided by O-Rings (FKM for aqueous synthesis and FFKM for organic synthesis). Other reactor elements that are in contact only with an external thermostatic bath are made of PEEK (electrodes holders and fittings), PTFE\/FEP (tubbing), zinc plated steel (adjustable hook clamps). O-Rings exposed to the thermostatic bath are made of FKM. The construction is liquid tight. Operational temperatures lay in a range of -25 up to 200 deg C. The cell may be adopted to broader temperature range on request (-45 up to 300 deg).\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication note:\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003eTypical applications include a) electrochemical electrosynthesis in organic and aqueous electrolytes (anodic oxidation, cathodic reductions, redox reactions and electrofluorination), b) electrochemical waste-water treatment and c) electrochemical pre-treatment prior to biological processes. \u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecification:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003enominal electrode exposure area: 1 cm\u003csup data-mce-fragment=\"1\"\u003e2\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e(11.3 mm dia.)\u003cbr data-mce-fragment=\"1\"\u003enominal membrane exposure area: 1 cm\u003csup data-mce-fragment=\"1\"\u003e2\u003c\/sup\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e(11.3 mm dia.)\u003cbr data-mce-fragment=\"1\"\u003eelectrolyte volume: 2.5 mL\/chamber\u003cbr data-mce-fragment=\"1\"\u003eelectrode distance: ~30 mm\u003cbr data-mce-fragment=\"1\"\u003eadditional electrode diameter: 6 mm\u003cbr data-mce-fragment=\"1\"\u003eelectrode size: 15 mm x 15 mm x 0.5\u003cbr data-mce-fragment=\"1\"\u003emembrane size: 20 – 25 mm dia., \u0026lt;1 mm thick\u003cbr data-mce-fragment=\"1\"\u003echamber material: Titanium grade 7\u003cbr data-mce-fragment=\"1\"\u003emaximum operational temperature: 200 deg C\u003cbr data-mce-fragment=\"1\"\u003eminimum operational temperature: -20 deg C\u003cbr data-mce-fragment=\"1\"\u003etubbing size: 2 mm ID, 3 mm OD\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntrastat data:\u003c\/strong\u003e\u003cbr\u003eHS Code: 90309000\u003cbr\u003eCountry of Origin: Sweden\u003cbr\u003eNET weight: 300 g\u003cbr\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eProduct includes:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e1 x Titanium anode compartment\u003cbr data-mce-fragment=\"1\"\u003e1 x Titanium cathode compartment\u003cbr data-mce-fragment=\"1\"\u003e1 x Titanium plug\u003cbr data-mce-fragment=\"1\"\u003e2 x PEEK sample holder\u003cbr data-mce-fragment=\"1\"\u003e2 x copper foil back-contact\u003cbr data-mce-fragment=\"1\"\u003e2 x rod contact\u003cbr data-mce-fragment=\"1\"\u003e2 x adjustable hook clamps\u003cbr data-mce-fragment=\"1\"\u003e2 x guides\u003cbr data-mce-fragment=\"1\"\u003e1 x set of O-rings\u003cbr data-mce-fragment=\"1\"\u003e4 x flangeless nuts for gas intel\/outlet (3 mm OD tubing)\u003cbr data-mce-fragment=\"1\"\u003e4 x flangeless ferrules (3 mm OD tubing)\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Redoxme","offers":[{"title":"Aqueous electrolyte experiment","offer_id":43365405982901,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic solvent-based electrolyte experiment","offer_id":43365406015669,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/1_1024x1024_540x_9ec9d8c6-f0bd-42f7-bc27-98723f0df124.png?v=1701330257"},{"product_id":"photo-bioelectrochemical-reactor-2-x-50-ml","title":"PHOTO-BIOELECTROCHEMICAL REACTOR 2 X 50 ML","description":"\u003cdiv class=\"product-description rte\" data-mce-fragment=\"1\" itemprop=\"description\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis photo-bioelectrochemical (microbial) reactor is used to generate electricity upon irradiation of biomaterial-functionalized electrodes in aqueous solutions. In a classical photolysis experiment the solar Illumination of the photoanode yields the oxidation of water to O2 and the transfer of electrons through the external circuit to the cathode, where O2 is re-reduced to water. This setup may operate as one H-Cell (two chamber system with a membrane in between electrodes) or as two separated single chamber systems when using the chamber end caps (not included in the set). The H-cell configuration also offers the possibility to run the device as a microbial electrolysis cell, where hydrogen gas is produced at the cathode.\u003cbr\u003eThe current collectors for (photo-)bioanode and\/or (photo-)biocathode as well and standard metal- or carbon-based anodes and cathodes, are available for that cell. A convenient way to install (photo-)electrodes can be realized using Tantalum wire clips.\u003cbr\u003eVarious chamber types are available for that cell. A default configuration contains one quartz chamber (tube) and one opaque chamber. Other chambers are available on request.\u003cbr\u003eWhen choosing an artificial light source for this setup one needs to consider the absorption maxima of the photo-electrode. Because light is a necessity in photo-bioelectrochemical studies, care must be taken on possible abiotic side effects of illumination. This includes warming up of the setup due to intense illumination. To optimize the irradiation of the system and be able to adjust the intensity (too high light intensities will lower the efficiency) redox.me recommends two light sources: 1) LED Solar Simulator class AAA and 2) Switchable LED light source. A light intensity power meter (available on request) is also a useful tool when arranging the setup.\u003cbr\u003eThe cell elements are constructed with material that is inert to the studied biomaterial system (bio-compatible thermosetting resin highly loaded with glass beads). It well fits aqueous (FKM O-Rings) electrolyte requirements in a full pH spectrum. The construction is liquid- and gas-tight. Various membrane materials and thicknesses are compatible with this cell including nanoporous and ion-exchange membranes. \u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eApplication note:\u003cbr\u003e\u003c\/strong\u003eThe list of applications includes, but is not limited to microbial fuel cell, microbial electrolysis cell, microbial electrosynthesis (fuel and chemical production), microbial desalination cell, enzymatic biofuel cell and all the above variants with light irradiation (light supported) as well as microbial solar cell. Typically, microbes such as microalgae, electrogenic microalgae and photosynthetic bacteria are used to functionalize electrodes.\u003cbr\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecification:\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003emaximum volume: 2 x 50 mL\u003cbr\u003emembrane aperture: 1 cm\u003csup data-mce-fragment=\"1\"\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e(11.3 mm dia.)\u003cbr data-mce-fragment=\"1\"\u003erecommended membrane diameter: 25 mm\u003cbr\u003eelectrode plug diameter: 6 mm\u003cbr data-mce-fragment=\"1\"\u003estopper diameter: 14 mm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntrastat data:\u003c\/strong\u003e\u003cbr\u003eHS Code: 90309000\u003cbr\u003eCountry of Origin: Sweden\u003cbr\u003eNET weight: 300 g\u003cbr\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eProduct includes:\u003cbr\u003e\u003c\/strong\u003e1 x cell base with adjustable hook clamps\u003cbr data-mce-fragment=\"1\"\u003e1 x cell base\u003cbr data-mce-fragment=\"1\"\u003e2 x lid\u003cbr data-mce-fragment=\"1\"\u003e1 x quartz chamber\u003cbr\u003e1 x opaque chamber\u003cbr data-mce-fragment=\"1\"\u003e6 x plug\u003cbr\u003e2 x rubber septum stopper\u003cbr\u003e2 x septum lock\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Redoxme","offers":[{"title":"Default Title","offer_id":43365417418933,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/1_540x_dd7c1e3c-30f9-4840-8cfa-d4338dcce9f2.png?v=1701331062"},{"product_id":"bulk-electrolysis-basic-cell-50-ml","title":"BULK ELECTROLYSIS BASIC CELL - 50 ML","description":"\u003cp\u003eThis is a standard bulk electrolysis cell with basic configuration (known also as potentiostatic coulometry cell or controlled potential coulometry cell). The cell consists of three electrodes: working electrode (reticulated glassy carbon electrode), counter electrodes (Platinum wire), and reference electrode (typically \u003cspan data-mce-fragment=\"1\"\u003eAg\/AgCl\u003c\/span\u003e). The working and counter electrode are installed in the same compartment, while the reference electrode is separated by a ceramic frit. Reticulated glassy (vitreous) carbon electrode provides a large surface area to solution volume ratio. Electrode arrangement and possibility to use magnetic stirring ensure very efficient mass transport conditions. The cell elements are constructed with materials that are inert to the sample (glass and PEEK). It well fits aqueous (FKM\/EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight. See the assembly demonstration\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/redox.me\/blogs\/demonstrators\/bulk-electrolysis-basic-cell-50-ml\" title=\"bulk electrolysis demonstration\" target=\"_blank\" data-mce-href=\"https:\/\/redox.me\/blogs\/demonstrators\/bulk-electrolysis-basic-cell-50-ml\" data-mce-fragment=\"1\"\u003ehere\u003c\/a\u003e. The cell chamber is available in several material variants\u003cspan\u003e \u003c\/span\u003e\u003ca title=\"cell chamber\" href=\"https:\/\/wholesale.redox.me\/collections\/accessories\/products\/50-ml-cell-chamber\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/wholesale.redox.me\/collections\/accessories\/products\/50-ml-cell-chamber\" target=\"_blank\"\u003ehere\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eApplication note:\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eUsually, electrolysis is carried out under potentiostatic conditions by stepping the potential from a value where no faradaic current is observed to one where the reaction is mass transport-controlled. Typical applications of bulk electrolysis include complete oxidation or reduction of species, the complete synthesis of a product through electrochemical processes (small-scale preparative electrosynthesis and electroseparation), partial oxidation or reduction of a compound to change the ratio of oxidized and reduced species and studying the complexity of the reaction mechanism (e.g. coupled reactions).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003cstrong\u003eSpecification:\u003cbr\u003e\u003c\/strong\u003e\u003cspan\u003emaximum electrolyte volume: 50 mL\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eelectrode plug diameter: 6 mm\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003ecounter electrode: Platinum wire, 0.6 mm dia., 250 mm long\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eworking electrode: reticulated glassy carbon (RGC)\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eRGC bulk density: 0.05 g\/cm3\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eRGC porosity: 96.5 %\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eRGC resistivity: 400 µΩ·cm\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eRGC number of pores: 24 pores\/cm (60 pores\/inch)\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eRGC wire contact: Tantalum wire, 0.6 mm dia., 60 mm long\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIntrastat data\u003c\/strong\u003e\u003cbr\u003eHS Code: 85433070\u003cbr\u003eCountry of Origin: Sweden\u003cbr\u003eNET weight: 100 g\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct includes:\u003c\/strong\u003e\u003cbr\u003e1 x lid – 0011CPEMA\u003cbr\u003e1 x glass chamber – 0012PGLMA\u003cbr\u003e1 x plug – 0005CPEMA\u003cbr\u003e1 x Metal Wire Auxiliary Electrode – 50HX15 0.6\/250 mm, Platinum\u003cbr\u003e1 x Reticulated Glassy (Vitreous) Carbon Electrode\u003cbr\u003e1 x Ag\/AgCl or non-aqueous Ag\/Ag+ 70 mm reference electrode\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Redoxme","offers":[{"title":"Water-based electrolyte","offer_id":43365643288757,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Organic electrolyte","offer_id":43365643321525,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/1_540x_421b59c5-6104-4665-ad7a-f5945e6ccb53.png?v=1701336196"},{"product_id":"origasens-reference-electrode-calomel-103mm-ref921","title":"Reference Electrode Calomel 103mm (REF921)","description":"\u003cdiv class=\"ox-spacer\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ox-text ox-margin-bottom-medium PBShortTxt\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhy do we use reference electrodes?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe use of a reference electrode enables the comparison of the potentials of different indicator electrodes immersed in the same solution or the potential of the same indicator electrode immersed in different solutions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA reference electrode provides a stable potential whatever the measurement conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eAttribute\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eReference \u003c\/span\u003e\u003cspan\u003eElement\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrolyte\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eLiCl \u003c\/span\u003e\u003cspan\u003e1 \u003c\/span\u003e\u003cspan\u003eM\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eType\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eSimilar \u003c\/span\u003e\u003cspan\u003eto\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eREF921\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eTemperature \u003c\/span\u003e\u003cspan\u003eRange\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e0°C \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003e60°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eHigher \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e12 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eLower \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e8 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLength\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e103 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eJunction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003ePorous \u003c\/span\u003e\u003cspan\u003ePin\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGrinded\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eScrew \u003c\/span\u003e\u003cspan\u003eHead \u003c\/span\u003e\u003cspan\u003eS7\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Origalys","offers":[{"title":"Default Title","offer_id":52091739046069,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/OrigaSens-ReferenceElectrodeCalomel120mmGrinded_XR110_d0f9a4ff-e142-4786-8324-ccbb10fd9953.png?v=1765419612"},{"product_id":"origasens-reference-electrode-hg-hg2so4-120mm-grinded","title":"Reference Electrode Hg\/Hg2SO4 120mm Grinded","description":"\u003cdiv class=\"ox-spacer\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ox-text ox-margin-bottom-medium PBShortTxt\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhy do we use reference electrodes?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe use of a reference electrode enables the comparison of the potentials of different indicator electrodes immersed in the same solution or the potential of the same indicator electrode immersed in different solutions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA reference electrode provides a stable potential whatever the measurement conditions.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eAttribute\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eReference \u003c\/span\u003e\u003cspan\u003eElement\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHg\/Hg₂SO₄\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrolyte\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eSaturated \u003c\/span\u003e\u003cspan\u003eK₂SO₄\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eTemperature \u003c\/span\u003e\u003cspan\u003eRange\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e0°C \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003e60°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eSimilar \u003c\/span\u003e\u003cspan\u003eto\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eDrawing \u003c\/span\u003e\u003cspan\u003eNumber\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eUpper \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e12 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eLower \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e8 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLength\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e120 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eJunction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePorous–Porous\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eScrew \u003c\/span\u003e\u003cspan\u003eHead, \u003c\/span\u003e\u003cspan\u003eS7\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Origalys","offers":[{"title":"Default Title","offer_id":52091770962101,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/OrigaSens-ReferenceElectrodeAg-AgCl120mm-007_be13f95e-2bea-46b8-afbf-36c23cfeeeca.png?v=1765419678"},{"product_id":"origasens-reference-electrode-hg-hg2so4-103mm-ref621","title":"Reference electrode Hg\/Hg2SO4 103mm (REF621)","description":"\u003cdiv class=\"ox-spacer\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ox-text ox-margin-bottom-medium PBShortTxt\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhy do we use reference electrodes?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe use of a reference electrode enables the comparison of the potentials of different indicator electrodes immersed in the same solution or the potential of the same indicator electrode immersed in different solutions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA reference electrode provides a stable potential whatever the measurement conditions.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eAttribute\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eReference \u003c\/span\u003e\u003cspan\u003eElement\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHg\/Hg₂SO₄\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrolyte\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eSaturated \u003c\/span\u003e\u003cspan\u003eK₂SO₄\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eTemperature \u003c\/span\u003e\u003cspan\u003eRange\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e0°C \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003e60°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eSimilar \u003c\/span\u003e\u003cspan\u003eto\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eREF621\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eDrawing \u003c\/span\u003e\u003cspan\u003eNumber\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eUpper \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e12 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eLower \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e8 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLength\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e103 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eJunction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePorous–Porous\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eScrew \u003c\/span\u003e\u003cspan\u003eHead, \u003c\/span\u003e\u003cspan\u003eS7\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e","brand":"Origalys","offers":[{"title":"Default Title","offer_id":52091780432053,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/OrigaSens-ReferenceelectrodeHg-Hg2SO4103mm_REF621.png?v=1765415771"},{"product_id":"origasens-reference-electrode-ag-agcl-120mm-double-junction","title":"Reference Electrode Ag\/AgCl 120mm Double Junction","description":"\u003cdiv class=\"ox-spacer\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ox-text ox-margin-bottom-medium PBShortTxt\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhy do we use reference electrodes?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe use of a reference electrode enables the comparison of the potentials of different indicator electrodes immersed in the same solution or the potential of the same indicator electrode immersed in different solutions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA reference electrode provides a stable potential whatever the measurement conditions.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eAttribute\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eReference \u003c\/span\u003e\u003cspan\u003eElement\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAg\/AgCl\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrolyte\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e3 \u003c\/span\u003e\u003cspan\u003eM \u003c\/span\u003e\u003cspan\u003eKCl \u003c\/span\u003e\u003cspan\u003ewith \u003c\/span\u003e\u003cspan\u003esaturated \u003c\/span\u003e\u003cspan\u003eAgCl\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eType\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eSimilar \u003c\/span\u003e\u003cspan\u003eto\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eTemperature \u003c\/span\u003e\u003cspan\u003eRange\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e–10°C \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003e100°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eUpper \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e12 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eLower \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e8 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLength\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e120 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eJunction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePorous–Porous\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGrinded\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eScrew \u003c\/span\u003e\u003cspan\u003eHead, \u003c\/span\u003e\u003cspan\u003eS7\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e","brand":"Origalys","offers":[{"title":"Default Title","offer_id":52091788099765,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/OrigaSens-ReferenceElectrodeAg-AgCl120mm-007_ba6a14df-f0b6-4c0e-af4a-8ce1ff8b0418.png?v=1765419719"},{"product_id":"origasens-reference-electrode-hg-hgo","title":"Reference Electrode Hg\/HgO","description":"\u003cdiv class=\"ox-spacer\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ox-text ox-margin-bottom-medium PBShortTxt\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhy do we use reference electrodes?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe use of a reference electrode enables the comparison of the potentials of different indicator electrodes immersed in the same solution or the potential of the same indicator electrode immersed in different solutions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA reference electrode provides a stable potential whatever the measurement conditions.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eAttribute\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eReference \u003c\/span\u003e\u003cspan\u003eElement\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHg\/HgO\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrolyte\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e0.1 \u003c\/span\u003e\u003cspan\u003eM \u003c\/span\u003e\u003cspan\u003eKOH\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eType\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eE10.OGL.026\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eSimilar \u003c\/span\u003e\u003cspan\u003eto\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eXR400\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eTemperature \u003c\/span\u003e\u003cspan\u003eRange\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e–5°C \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003e50°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eUpper \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e12 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eLower \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e8 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLength\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e120 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eLiquid \u003c\/span\u003e\u003cspan\u003eJunction\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003ePorous \u003c\/span\u003e\u003cspan\u003ePin\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGrinded\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eScrew \u003c\/span\u003e\u003cspan\u003eHead, \u003c\/span\u003e\u003cspan\u003eS7\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e","brand":"Origalys","offers":[{"title":"Default Title","offer_id":52091792588981,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/OrigaSens-ReferenceElectrodeHg-HgO.png?v=1765416158"},{"product_id":"origasens-reference-electrode-hg-hgo-grinded","title":"Reference Electrode Hg\/HgO Grinded","description":"\u003cdiv class=\"ox-spacer\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ox-text ox-margin-bottom-medium PBShortTxt\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhy do we use reference electrodes?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe use of a reference electrode enables the comparison of the potentials of different indicator electrodes immersed in the same solution or the potential of the same indicator electrode immersed in different solutions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA reference electrode provides a stable potential whatever the measurement conditions.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eAttribute\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eReference \u003c\/span\u003e\u003cspan\u003eElement\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHg\/HgO\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrolyte\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e0.1 \u003c\/span\u003e\u003cspan\u003eM \u003c\/span\u003e\u003cspan\u003eKOH\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eType\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eE10.OGL.027\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eSimilar \u003c\/span\u003e\u003cspan\u003eto\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eXR400 \u003c\/span\u003e\u003cspan\u003e(grinded)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eTemperature \u003c\/span\u003e\u003cspan\u003eRange\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e–5°C \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003e50°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eUpper \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e12 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eLower \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e8 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLength\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e120 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eLiquid \u003c\/span\u003e\u003cspan\u003eJunction\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003ePorous \u003c\/span\u003e\u003cspan\u003ePin\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGrinded\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eScrew \u003c\/span\u003e\u003cspan\u003eHead, \u003c\/span\u003e\u003cspan\u003eS7\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e","brand":"Origalys","offers":[{"title":"Default Title","offer_id":52091796226229,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/OrigaSens-ReferenceElectrodeHg-HgOGrinded.png?v=1765416383"},{"product_id":"origasens-reference-electrode-calomel-120mm-grinded-xr110","title":"Reference Electrode Calomel 120mm Grinded (XR110)","description":"\u003cdiv class=\"ox-spacer\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ox-text ox-margin-bottom-medium PBShortTxt\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhy do we use reference electrodes?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe use of a reference electrode enables the comparison of the potentials of different indicator electrodes immersed in the same solution or the potential of the same indicator electrode immersed in different solutions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA reference electrode provides a stable potential whatever the measurement conditions.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ox-text ox-margin-bottom-medium PBShortTxt\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eAttribute\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eReference \u003c\/span\u003e\u003cspan\u003eElement\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrolyte\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eSaturated \u003c\/span\u003e\u003cspan\u003eKCl\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eType\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eE11.OGL.002\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eSimilar \u003c\/span\u003e\u003cspan\u003eto\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eXR110\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eTemperature \u003c\/span\u003e\u003cspan\u003eRange\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e–10°C \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003e50°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eUpper \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e12 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eLower \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e8 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLength\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e120 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eLiquid \u003c\/span\u003e\u003cspan\u003eJunction\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003ePorous \u003c\/span\u003e\u003cspan\u003ePin\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGrinded\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eScrew \u003c\/span\u003e\u003cspan\u003eHead, \u003c\/span\u003e\u003cspan\u003eS7\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Origalys","offers":[{"title":"Default Title","offer_id":52091801895093,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/OrigaSens-ReferenceElectrodeCalomel120mmGrinded_XR110.png?v=1765416667"},{"product_id":"origasens-reference-electrode-calomel-103mm-ref421","title":"Reference Electrode Calomel 103mm (REF421)","description":"\u003cdiv class=\"ox-spacer\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ox-text ox-margin-bottom-medium PBShortTxt\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhy do we use reference electrodes?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe use of a reference electrode enables the comparison of the potentials of different indicator electrodes immersed in the same solution or the potential of the same indicator electrode immersed in different solutions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA reference electrode provides a stable potential whatever the measurement conditions.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eAttribute\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eReference \u003c\/span\u003e\u003cspan\u003eElement\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrolyte\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eSaturated \u003c\/span\u003e\u003cspan\u003eKCl\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eType\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eE11.OGL.003\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eSimilar \u003c\/span\u003e\u003cspan\u003eto\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eREF421\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eTemperature \u003c\/span\u003e\u003cspan\u003eRange\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e–5°C \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003e50°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eUpper \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e12 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eLower \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e8 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLength\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e103 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eLiquid \u003c\/span\u003e\u003cspan\u003eJunction\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003ePorous \u003c\/span\u003e\u003cspan\u003ePin\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGrinded\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eScrew \u003c\/span\u003e\u003cspan\u003eHead, \u003c\/span\u003e\u003cspan\u003eS7\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Origalys","offers":[{"title":"Default Title","offer_id":52091835809973,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/OrigaSens-ReferenceElectrodeCalomel103mm_REF421.png?v=1765417198"},{"product_id":"origasens-reference-electrode-ag-agcl-103mm-ref321","title":"Reference Electrode Ag\/AgCl 103mm (REF321)","description":"\u003cdiv class=\"ox-spacer\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ox-text ox-margin-bottom-medium PBShortTxt\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhy do we use reference electrodes?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe use of a reference electrode enables the comparison of the potentials of different indicator electrodes immersed in the same solution or the potential of the same indicator electrode immersed in different solutions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA reference electrode provides a stable potential whatever the measurement conditions.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eAttribute\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eReference \u003c\/span\u003e\u003cspan\u003eElement\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAg\/AgCl\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrolyte\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e3 \u003c\/span\u003e\u003cspan\u003eM \u003c\/span\u003e\u003cspan\u003eKCl \u003c\/span\u003e\u003cspan\u003ewith \u003c\/span\u003e\u003cspan\u003esaturated \u003c\/span\u003e\u003cspan\u003eAgCl\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eType\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eE11.OGL.014\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eSimilar \u003c\/span\u003e\u003cspan\u003eto\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eREF321\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eTemperature \u003c\/span\u003e\u003cspan\u003eRange\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e–5°C \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003e80°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eUpper \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e12 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eLower \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e8 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLength\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e103 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eLiquid \u003c\/span\u003e\u003cspan\u003eJunction\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003ePorous \u003c\/span\u003e\u003cspan\u003ePin\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGrinded\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eScrew \u003c\/span\u003e\u003cspan\u003eHead, \u003c\/span\u003e\u003cspan\u003eS7\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e","brand":"Origalys","offers":[{"title":"Default Title","offer_id":52091846787253,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/OrigaSens-ReferenceElectrodeAg-AgCl103mm_REF321.png?v=1765417571"},{"product_id":"origasens-reference-electrode-ag-agcl-120mm","title":"Reference Electrode Ag\/AgCl 120mm (Code: OGR006)","description":"\u003cdiv class=\"ox-spacer\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ox-text ox-margin-bottom-medium PBShortTxt\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhy do we use reference electrodes?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe use of a reference electrode enables the comparison of the potentials of different indicator electrodes immersed in the same solution or the potential of the same indicator electrode immersed in different solutions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA reference electrode provides a stable potential whatever the measurement conditions.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eAttribute\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eReference \u003c\/span\u003e\u003cspan\u003eElement\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAg\/AgCl\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrolyte\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e3 \u003c\/span\u003e\u003cspan\u003eM \u003c\/span\u003e\u003cspan\u003eKCl \u003c\/span\u003e\u003cspan\u003ewith \u003c\/span\u003e\u003cspan\u003esaturated \u003c\/span\u003e\u003cspan\u003eAgCl\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eType\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eE11.OGL.015\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eSimilar \u003c\/span\u003e\u003cspan\u003eto\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eXR300\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eTemperature \u003c\/span\u003e\u003cspan\u003eRange\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e–5°C \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003e80°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eUpper \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e12 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eLower \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e8 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLength\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e120 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eLiquid \u003c\/span\u003e\u003cspan\u003eJunction\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003ePorous \u003c\/span\u003e\u003cspan\u003ePin\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGrinded\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eScrew \u003c\/span\u003e\u003cspan\u003eHead, \u003c\/span\u003e\u003cspan\u003eS7\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e","brand":"Origalys","offers":[{"title":"Default Title","offer_id":52091854782645,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/OrigaSens-ReferenceElectrodeAg-AgCl120mm-007_a81a46e0-a2bd-4fea-abff-ead66f15a4f3.png?v=1765419449"},{"product_id":"origasens-reference-electrode-ag-agcl-120mm-code-ogr007","title":"Reference Electrode Ag\/AgCl 120mm (Code: OGR007)","description":"\u003cdiv class=\"ox-spacer\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ox-text ox-margin-bottom-medium PBShortTxt\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhy do we use reference electrodes?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe use of a reference electrode enables the comparison of the potentials of different indicator electrodes immersed in the same solution or the potential of the same indicator electrode immersed in different solutions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA reference electrode provides a stable potential whatever the measurement conditions.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eAttribute\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eReference \u003c\/span\u003e\u003cspan\u003eElement\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAg\/AgCl\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrolyte\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e3 \u003c\/span\u003e\u003cspan\u003eM \u003c\/span\u003e\u003cspan\u003eKCl \u003c\/span\u003e\u003cspan\u003ewith \u003c\/span\u003e\u003cspan\u003esaturated \u003c\/span\u003e\u003cspan\u003eAgCl\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eType\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eE12.OGL.058\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eSimilar \u003c\/span\u003e\u003cspan\u003eto\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eTemperature \u003c\/span\u003e\u003cspan\u003eRange\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e–10°C \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003e100°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eUpper \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e12 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eLower \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e6 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLength\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e120 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eLiquid \u003c\/span\u003e\u003cspan\u003eJunction\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003ePorous \u003c\/span\u003e\u003cspan\u003ePin\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGrinded\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eScrew \u003c\/span\u003e\u003cspan\u003eHead, \u003c\/span\u003e\u003cspan\u003eS7\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e","brand":"Origalys","offers":[{"title":"Default Title","offer_id":52091872313525,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/OrigaSens-ReferenceElectrodeAg-AgCl120mm-007.png?v=1765418573"},{"product_id":"origasens-similar-red-rod-reference-electrode","title":"Similar Red Rod Reference Electrode","description":"\u003cdiv class=\"ox-spacer\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ox-text ox-margin-bottom-medium PBShortTxt\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhy do we use reference electrodes?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe use of a reference electrode enables the comparison of the potentials of different indicator electrodes immersed in the same solution or the potential of the same indicator electrode immersed in different solutions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA reference electrode provides a stable potential whatever the measurement conditions.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eAttribute\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eReference \u003c\/span\u003e\u003cspan\u003eElement\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eSimilar \u003c\/span\u003e\u003cspan\u003eRed \u003c\/span\u003e\u003cspan\u003eRod \u003c\/span\u003e\u003cspan\u003e(Ag\/AgCl)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrolyte\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eSaturated \u003c\/span\u003e\u003cspan\u003eKCl\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eType\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eE13.OGL.011\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eSimilar \u003c\/span\u003e\u003cspan\u003eto\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eREF201\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eTemperature \u003c\/span\u003e\u003cspan\u003eRange\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e–10°C \u003c\/span\u003e\u003cspan\u003eto \u003c\/span\u003e\u003cspan\u003e100°C\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eUpper \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e12 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eLower \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e8 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLength\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e103 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eLiquid \u003c\/span\u003e\u003cspan\u003eJunction\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003ePorous \u003c\/span\u003e\u003cspan\u003ePin\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGrinded\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eScrew \u003c\/span\u003e\u003cspan\u003eHead, \u003c\/span\u003e\u003cspan\u003eS7\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e","brand":"Origalys","offers":[{"title":"Default Title","offer_id":52091877949621,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/OrigaSens-ReferenceElectrodeAg-AgCl120mm-007_b1da19e4-f115-4de0-a6b4-04f57f02e602.png?v=1765419398"},{"product_id":"origasens-platinum-grid-counter-electrode","title":"Platinum grid counter-electrode","description":"\u003ch3\u003eDescription:\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eDurable platinum grid counter-electrode designed for stability and efficiency, featuring a robust build and wide contact surface for reliable electrochemical performance.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003especifications:\u003c\/h3\u003e\n\u003cdiv class=\"ox-tabs-pane is-active\"\u003e\n\u003cdiv class=\"ox-div\"\u003e\n\u003cdiv class=\"ox-columns ox-columns-sep-small ox-columns--col-2\"\u003e\n\u003cdiv class=\"ox-column col-xs-8\"\u003e\n\u003cdiv class=\"ox-text ox-margin-bottom-medium\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eLength: 152 mm\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBasket diameter: 32 mm\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWire diameter: 0.12 mm\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBasket Height: 50 mm\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMesh: 225 M\/cm²\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaterial: 100% Platinum\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ox-clear-fix\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Origalys","offers":[{"title":"Default Title","offer_id":52099684696245,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/platiniumCounterelectrode.png?v=1765789818"},{"product_id":"origasens-voltammetry-electrode-platinum-plate-8x8-120mm","title":"Voltammetry Electrode Platinum Plate 8x8 120mm","description":"\u003ch3\u003eDescription:\u003c\/h3\u003e\n\u003cp\u003eOrigaSens Voltammetry Electrode with platinum plate (8×8 mm, 120 mm length), engineered for precise and reliable electrochemical measurements.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003especifications:\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"ox-tabs-pane is-active\"\u003e\n\u003cdiv class=\"ox-div\"\u003e\n\u003cdiv class=\"ox-columns ox-columns-sep-small ox-columns--col-2\"\u003e\n\u003cdiv class=\"ox-clear-fix\"\u003e\n\u003ctable style=\"width: 100.036%; height: 215.6px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 51.1943%; height: 19.6px;\"\u003e\u003cspan\u003e Sensing element\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 46.3458%; height: 19.6px;\"\u003e\u003cspan\u003ePlatinum Plate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 51.1943%; height: 19.6px;\" class=\"\"\u003e\u003cspan\u003e Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 46.3458%; height: 19.6px;\" class=\"\"\u003e 8x8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 51.1943%; height: 19.6px;\"\u003e\u003cspan\u003e Draw\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 46.3458%; height: 19.6px;\"\u003e\u003cspan\u003e-\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 51.1943%; height: 19.6px;\"\u003e Similar to\u003c\/td\u003e\n\u003ctd style=\"width: 46.3458%; height: 19.6px;\"\u003eXM140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 51.1943%; height: 19.6px;\"\u003e Temperature\u003c\/td\u003e\n\u003ctd style=\"width: 46.3458%; height: 19.6px;\"\u003e-10°C to 100°C\u003cspan\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 51.1943%; height: 19.6px;\"\u003e Higher diameter\u003c\/td\u003e\n\u003ctd style=\"width: 46.3458%; height: 19.6px;\"\u003e12 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 51.1943%; height: 19.6px;\"\u003e Lower diamter\u003c\/td\u003e\n\u003ctd style=\"width: 46.3458%; height: 19.6px;\"\u003e8 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 51.1943%; height: 19.6px;\"\u003e Length\u003c\/td\u003e\n\u003ctd style=\"width: 46.3458%; height: 19.6px;\"\u003e120 mm\u003cspan\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 51.1943%; height: 19.6px;\"\u003e Junction\u003c\/td\u003e\n\u003ctd style=\"width: 46.3458%; height: 19.6px;\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 51.1943%; height: 19.6px;\"\u003e Grinded\u003c\/td\u003e\n\u003ctd style=\"width: 46.3458%; height: 19.6px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 51.1943%; height: 19.6px;\"\u003e Connection\u003c\/td\u003e\n\u003ctd style=\"width: 46.3458%; height: 19.6px;\"\u003e\n\u003cspan\u003e Screw Head\u003c\/span\u003e S7\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Origalys","offers":[{"title":"Default Title","offer_id":52099750658229,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/OrigaSens-VoltammetryElectrodePlatinumPlate8x8120mm.png?v=1765790536"},{"product_id":"voltammetry-electrode-platinum-disc-o10-103mm","title":"Voltammetry Electrode Platinum Disc Ø10 103mm","description":"\u003ch3\u003eDescription:\u003c\/h3\u003e\n\u003cp\u003eOrigaSens - Voltammetry Electrode with platinum disc (Ø10 mm, 103 mm length), designed for precise and stable electrochemical measurements.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003especifications:\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSensing element\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlatinum Disc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"\"\u003e\u003cspan\u003e Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"\"\u003e 10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e Draw\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Similar to\u003c\/td\u003e\n\u003ctd\u003eXM150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C à 100°C\u003cspan\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Higher diameter\u003c\/td\u003e\n\u003ctd\u003e12 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Lower diameter\u003c\/td\u003e\n\u003ctd\u003e12 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Length\u003c\/td\u003e\n\u003ctd\u003e103 mm\u003cspan\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Junction\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Grinded\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Connection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e \u003c\/span\u003eScrew Head S7\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Origalys","offers":[{"title":"Default Title","offer_id":52100195745973,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/VoltammetryElectrodePlatinumDiscO10103mm.png?v=1765791817"},{"product_id":"voltammetry-electrode-pt-98-5mm","title":"Voltammetry Electrode Pt 98,5mm","description":"\u003ch3\u003eDescription:\u003c\/h3\u003e\n\u003cp\u003eOrigaSens - Voltammetry Electrode with platinum tip (Ø0.98 mm, 85 mm length), built for accurate and durable electrochemical measurements.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e Sensing element\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlatinum Disc 10 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"\"\u003e\u003cspan\u003e Disc thickness\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"\"\u003e \u003cspan\u003e0,3 mm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eE11.OGL.025\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Similar to\u003c\/td\u003e\n\u003ctd\u003eCE-PTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 80°C\u003cspan\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Higher diameter\u003c\/td\u003e\n\u003ctd\u003e12 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Lower diameter\u003c\/td\u003e\n\u003ctd\u003e10 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Length\u003c\/td\u003e\n\u003ctd\u003e98,5 mm\u003cspan\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Junction\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Grinded\u003c\/td\u003e\n\u003ctd\u003eNon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Connection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e \u003c\/span\u003eScrew Head S7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Origalys","offers":[{"title":"Default Title","offer_id":52100315218101,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/OrigaSens-VoltammetryElectrodePt98_5mm.png?v=1765792258"},{"product_id":"metal-electrode-silver","title":"Metal Electrode Silver","description":"\u003ch3\u003eDescription:\u003c\/h3\u003e\n\u003cp\u003eOrigaSens - Silver Metal Electrode, designed for reliable electrochemical measurements with stable performance and durability.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e Sensing element\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSilver Rod 3mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"\"\u003e\u003cspan\u003e Electrolyte\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"\"\u003e \u003cspan\u003e-\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eE13.OGL.008\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Similar to\u003c\/td\u003e\n\u003ctd\u003eM291Ag \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 80°C\u003cspan\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Higher diameter\u003c\/td\u003e\n\u003ctd\u003e12 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Lower diameter\u003c\/td\u003e\n\u003ctd\u003e8 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Length\u003c\/td\u003e\n\u003ctd\u003e103 mm\u003cspan\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Junction\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Grinded\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Connection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e \u003c\/span\u003eScrew Head S7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Origalys","offers":[{"title":"Default Title","offer_id":52100423123125,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/OrigaSens-MetalElectrodeSilver.png?v=1765792451"},{"product_id":"voltammetry-electrode-pt-wire-103mm","title":"Voltammetry Electrode Pt Wire 103mm","description":"\u003ch3\u003eDescription:\u003c\/h3\u003e\n\u003cp\u003eOrigaSens - Voltammetry Electrode with platinum wire (Ø1 mm, 103 mm length), offering precision and durability for electrochemical experiments.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e Sensing element\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlatinum Wire\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"\"\u003e\u003cspan\u003e Wire diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"\"\u003e \u003cspan\u003e1 mm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eE12.OGL.038\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Similar to\u003c\/td\u003e\n\u003ctd\u003eM231Pt9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to 100°C\u003cspan\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Higher diameter\u003c\/td\u003e\n\u003ctd\u003e12 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Lower diameter\u003c\/td\u003e\n\u003ctd\u003e8 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Length\u003c\/td\u003e\n\u003ctd\u003e103 mm\u003cspan\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Junction\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Grinded\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Connection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e \u003c\/span\u003eScrew head S7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Origalys","offers":[{"title":"Default Title","offer_id":52100501602485,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/OrigaSens-VoltammetryElectrodePtWire103mm.png?v=1765792629"},{"product_id":"voltammetry-electrode-pt-wire-120mm","title":"Voltammetry Electrode Pt Wire 120mm","description":"\u003ch3\u003eDescription:\u003c\/h3\u003e\n\u003cp\u003eOrigaSens - Voltammetry Electrode with platinum wire (Ø1 mm, 120 mm length), designed for precise and durable electrochemical measurements.\u003c\/p\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e Sensing element\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlatinum Wire\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"\"\u003e\u003cspan\u003e Wire diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"\"\u003e \u003cspan\u003e1 mm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eE12.OGL.039\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Similar to\u003c\/td\u003e\n\u003ctd\u003eXM100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to 100°C\u003cspan\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Higher diameter\u003c\/td\u003e\n\u003ctd\u003e12 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Lower diameter\u003c\/td\u003e\n\u003ctd\u003e8 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Length\u003c\/td\u003e\n\u003ctd\u003e120 mm\u003cspan\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Junction\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Grinded\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Connection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e \u003c\/span\u003eScrew Head S7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Origalys","offers":[{"title":"Default Title","offer_id":52100575985845,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/OrigaSens-VoltammetryElectrodePtWire120mm.png?v=1765792850"},{"product_id":"voltammetry-electrode-platinum-plate-5x5-103mm","title":"Voltammetry Electrode Platinum Plate 5x5 103mm","description":"\u003ch3\u003eDescription:\u003c\/h3\u003e\n\u003cp\u003eOrigaSens - Voltammetry Electrode with platinum plate (5×5 mm, 103 mm length), engineered for precise and stable electrochemical measurements.\u003c\/p\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e Sensing element\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlatinum Plate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"\"\u003e\u003cspan\u003e Plate diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"\"\u003e 5 x 5\u003cspan\u003e mm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eE12.OGL.056\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Similar to\u003c\/td\u003e\n\u003ctd\u003eM241Pt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C à 100°C\u003cspan\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Higher diameter\u003c\/td\u003e\n\u003ctd\u003e12 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Lower diameter\u003c\/td\u003e\n\u003ctd\u003e8 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Length\u003c\/td\u003e\n\u003ctd\u003e103 mm\u003cspan\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Junction\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Grinded\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Connection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e \u003c\/span\u003eScrew Head S7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Origalys","offers":[{"title":"Default Title","offer_id":52100663410869,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/OrigaSens-VoltammetryElectrodePlatinumPlate5x5120mm.png?v=1765793435"},{"product_id":"voltammetry-electrode-platinum-plate-5x5-120mm","title":"Voltammetry Electrode Platinum Plate 5x5 120mm","description":"\u003ch3\u003eDescription:\u003c\/h3\u003e\n\u003cp\u003eOrigaSens - Voltammetry Electrode with platinum plate (5×5 mm, 120 mm length), designed for precise and durable electrochemical measurements.\u003c\/p\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e Sensing element\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlatinum Plate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"\"\u003e\u003cspan\u003e Plate diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"\"\u003e 5 x 5\u003cspan\u003e mm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eE12.OGL.057\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Similar to\u003c\/td\u003e\n\u003ctd\u003eXM120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to 100°C\u003cspan\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Higher diameter\u003c\/td\u003e\n\u003ctd\u003e12 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Lower diameter\u003c\/td\u003e\n\u003ctd\u003e8 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Length\u003c\/td\u003e\n\u003ctd\u003e120 mm\u003cspan\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Junction\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Grinded\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Connection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e \u003c\/span\u003eScrew Head S7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Origalys","offers":[{"title":"Default Title","offer_id":52100798972085,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/OrigaSens-VoltammetryElectrodePlatinumPlate5x5120mm.png?v=1765793435"},{"product_id":"electrode-holder-rod-statrod-static-electrode","title":"Electrode Holder Rod - StaTrod - Static Electrode","description":"\u003ch3\u003eDescription:\u003c\/h3\u003e\n\u003cp\u003eThe StaTrod Static Electrode is a specialized laboratory accessory designed for electrochemical experiments. Made from PEEK (Polyether ether ketone), it offers excellent chemical resistance, mechanical strength, and durability, making it suitable for demanding research environments.\u003c\/p\u003e\n\u003cp\u003eThis electrode rod serves as both a holder and connector, ensuring stable positioning of electrode tips and secure electrical contact through its banana connector. By providing consistent alignment and reliable connectivity, the StaTrod enhances reproducibility in electrochemical measurements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThis product can be used for \u003cstrong\u003e\u003ca rel=\"noopener\" title=\"Electrode tips\" href=\"https:\/\/celsa.com.au\/products\/electrode-tips-origatip\" target=\"_blank\"\u003eelectrode tips\u003c\/a\u003e \u003c\/strong\u003e\u0026amp;\u003cstrong\u003e \u003ca rel=\"noopener\" href=\"https:\/\/celsa.com.au\/products\/origatip-sample-holder-origalys\" title=\"Sample holder\" target=\"_blank\"\u003eSample holder\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eProduct \u003c\/span\u003e\u003cspan\u003eName\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eStaTrod \u003c\/span\u003e\u003cspan\u003eStatic \u003c\/span\u003e\u003cspan\u003eElectrode\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eMaterial\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003ePEEK \u003c\/span\u003e\u003cspan\u003e(Polyether \u003c\/span\u003e\u003cspan\u003eether \u003c\/span\u003e\u003cspan\u003eketone)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eLength: \u003c\/span\u003e\u003cspan\u003e114 \u003c\/span\u003e\u003cspan\u003emm, \u003c\/span\u003e\u003cspan\u003eDiameter: \u003c\/span\u003e\u003cspan\u003e11 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eConnector \u003c\/span\u003e\u003cspan\u003eType\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eStandard \u003c\/span\u003e\u003cspan\u003ebanana \u003c\/span\u003e\u003cspan\u003econnector\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFunction\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eElectrode \u003c\/span\u003e\u003cspan\u003eholder \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003econnector \u003c\/span\u003e\u003cspan\u003erod\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eElectrochemical \u003c\/span\u003e\u003cspan\u003eexperiments \u003c\/span\u003e\u003cspan\u003ein \u003c\/span\u003e\u003cspan\u003eresearch, \u003c\/span\u003e\u003cspan\u003eteaching, \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003eindustry\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eKey \u003c\/span\u003e\u003cspan\u003eBenefits\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eChemical \u003c\/span\u003e\u003cspan\u003eresistance, \u003c\/span\u003e\u003cspan\u003emechanical \u003c\/span\u003e\u003cspan\u003edurability, \u003c\/span\u003e\u003cspan\u003estable \u003c\/span\u003e\u003cspan\u003eelectrode \u003c\/span\u003e\u003cspan\u003epositioning, \u003c\/span\u003e\u003cspan\u003ereproducible \u003c\/span\u003e\u003cspan\u003eresults\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCompatibility\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eElectrode \u003c\/span\u003e\u003cspan\u003etips \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003esample \u003c\/span\u003e\u003cspan\u003eholders\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Origalys","offers":[{"title":"Default Title","offer_id":52108073566389,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/electrodeholder.webp?v=1765880348"},{"product_id":"origatip-sample-holder-origalys","title":"Sample Holder - OrigaTip","description":"\u003ch3\u003eDescription:\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe OrigaTip Sample Holder available in two models (8 mm and 15 mm diameter), the OrigaTip Sample Holder – Stainless Steel Contact (Titanium contact also available as an option) is a precision‑engineered accessory designed for electrochemical experiments requiring stable sample mounting and reliable electrical contact. Manufactured from 316L stainless steel, it ensures durability, corrosion resistance, and consistent conductivity. This holder is compatible with \u003ca rel=\"noopener\" title=\"Rotating Disk Electrode\" href=\"https:\/\/celsa.com.au\/products\/rotating-disk-electrode-origatrod\" target=\"_blank\"\u003eOrigaTrod\u003c\/a\u003e, \u003ca rel=\"noopener\" title=\"Electrode Holder Rod - StaTrod - Static Electrode\" href=\"https:\/\/celsa.com.au\/products\/electrode-holder-rod-statrod-static-electrode\" target=\"_blank\"\u003eStaTrod\u003c\/a\u003e, and EDI101 electrode systems, making it a versatile tool for laboratories working with \u003ca rel=\"noopener\" title=\"Pellets\" href=\"https:\/\/celsa.com.au\/products\/sample-pellets-origatip\" target=\"_blank\"\u003epellets\u003c\/a\u003e and solid samples.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDelivered with a silicone O‑ring for secure sealing, the holder provides excellent sample stability during measurements. For specialized applications, a PTFE O‑ring option is available upon request, offering enhanced chemical resistance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis accessory is ideal for researchers and technicians who require reproducible sample positioning and robust contact in electrochemical setups.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ctable style=\"width: 100.036%; height: 196px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 34.8283%; height: 19.6px;\"\u003e\u003cspan\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"width: 62.7116%; height: 19.6px;\"\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.8283%; height: 19.6px;\"\u003e\u003cstrong\u003e\u003cspan\u003eProduct \u003c\/span\u003e\u003cspan\u003eCode\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7116%; height: 19.6px;\"\u003e\u003cspan\u003eE11OGL001CIAL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.8283%; height: 19.6px;\"\u003e\u003cstrong\u003e\u003cspan\u003eSample \u003c\/span\u003e\u003cspan\u003eHolder \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7116%; height: 19.6px;\"\u003e\n\u003cspan\u003eØ8 \u003c\/span\u003e\u003cspan\u003emm or Ø15 mm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 34.8283%; height: 39.2px;\"\u003e\u003cstrong\u003e\u003cspan\u003eCompatible \u003c\/span\u003e\u003cspan\u003eSample \u003c\/span\u003e\u003cspan\u003eThickness\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7116%; height: 39.2px;\"\u003e\n\u003cspan\u003e1–3 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.8283%; height: 19.6px;\"\u003e\u003cstrong\u003e\u003cspan\u003eContact \u003c\/span\u003e\u003cspan\u003eMaterial\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7116%; height: 19.6px;\"\u003e\n\u003cspan\u003eStainless \u003c\/span\u003e\u003cspan\u003eSteel \u003c\/span\u003e\u003cspan\u003e316L\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.8283%; height: 19.6px;\"\u003e\u003cstrong\u003e\u003cspan\u003eCompatibility\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7116%; height: 19.6px;\"\u003e\n\u003cspan\u003eOrigaTrod, \u003c\/span\u003e\u003cspan\u003eStaTrod, \u003c\/span\u003e\u003cspan\u003eEDI101\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.8283%; height: 19.6px;\"\u003e\u003cstrong\u003e\u003cspan\u003eSealing\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7116%; height: 19.6px;\"\u003e\n\u003cspan\u003eSupplied \u003c\/span\u003e\u003cspan\u003ewith \u003c\/span\u003e\u003cspan\u003esilicone \u003c\/span\u003e\u003cspan\u003eO-ring \u003c\/span\u003e\u003cspan\u003e(PTFE \u003c\/span\u003e\u003cspan\u003eavailable \u003c\/span\u003e\u003cspan\u003eon \u003c\/span\u003e\u003cspan\u003edemand)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.8283%; height: 19.6px;\"\u003e\u003cstrong\u003e\u003cspan\u003eApplication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7116%; height: 19.6px;\"\u003e\n\u003cspan\u003eElectrochemical \u003c\/span\u003e\u003cspan\u003eexperiments, \u003c\/span\u003e\u003cspan\u003epellet\/sample \u003c\/span\u003e\u003cspan\u003emounting\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.8283%; height: 19.6px;\"\u003e\u003cstrong\u003e\u003cspan\u003eDurability\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7116%; height: 19.6px;\"\u003e\n\u003cspan\u003eHigh \u003c\/span\u003e\u003cspan\u003ecorrosion \u003c\/span\u003e\u003cspan\u003eresistance, \u003c\/span\u003e\u003cspan\u003elong-term \u003c\/span\u003e\u003cspan\u003estability\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"product__description rte quick-add-hidden\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Origalys","offers":[{"title":"8 mm \/ Stainless Steel \/ Silicone O-ring","offer_id":52140574343349,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"8 mm \/ Stainless Steel \/ PTFE O-ring","offer_id":52153322176693,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"8 mm \/ Titanium \/ Silicone O-ring","offer_id":52140574376117,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"8 mm \/ Titanium \/ PTFE O-ring","offer_id":52153322209461,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"15 mm \/ Stainless Steel \/ Silicone O-ring","offer_id":52153322242229,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"15 mm \/ Stainless Steel \/ PTFE O-ring","offer_id":52153322274997,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"15 mm \/ Titanium \/ Silicone O-ring","offer_id":52153322307765,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"15 mm \/ Titanium \/ PTFE O-ring","offer_id":52153322340533,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/sampleholder8mm.webp?v=1765883075"},{"product_id":"sample-pellets-origatip","title":"Sample Pellets - OrigaTip","description":"\u003ch2\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eOrigaTip sample pellets are precision‑machined, disk‑shaped materials designed for use with OrigaLys electrochemical sample holders. They provide a standardized, interchangeable working surface for electrochemical testing, allowing researchers to quickly switch between materials without changing the entire electrode assembly.\u003c\/p\u003e\n\u003chr data-end=\"943\" data-start=\"940\"\u003e\n\u003ch2 data-end=\"978\" data-start=\"945\"\u003e\u003cstrong\u003eWhat the Sample Pellets Are\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe pellets come in a wide range of materials—including \u003cstrong\u003eboron‑doped diamond (BDD)\u003c\/strong\u003e, \u003cstrong\u003e316L stainless steel\u003c\/strong\u003e, \u003cstrong\u003ealuminium\u003c\/strong\u003e, \u003cstrong\u003ecopper\u003c\/strong\u003e, \u003cstrong\u003eglassy carbon\u003c\/strong\u003e, \u003cstrong\u003egold\u003c\/strong\u003e, \u003cstrong\u003egraphite\u003c\/strong\u003e, \u003cstrong\u003eiron\u003c\/strong\u003e, \u003cstrong\u003enickel\u003c\/strong\u003e, \u003cstrong\u003eplatinum\u003c\/strong\u003e, \u003cstrong\u003esilver\u003c\/strong\u003e, and \u003cstrong\u003etungsten steel\u003c\/strong\u003e—each offering distinct electrochemical properties suited to different applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePellets are available in two main diameters:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eØ8 mm\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eØ15 mm\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"940\" data-end=\"943\"\u003e\n\u003ch2\u003e\u003cstrong\u003eHow They Relate to the Sample Holders\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eEach pellet size corresponds directly to a specific \u003ca rel=\"noopener\" title=\"Sample Holder - OrigaTip\" href=\"https:\/\/celsa.com.au\/products\/origatip-sample-holder-origalys\" target=\"_blank\"\u003eOrigaTip sample holder\u003c\/a\u003e model:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eØ8 mm pellets\u003c\/strong\u003e fit the \u003cstrong\u003eSample Holder Ø8\u003c\/strong\u003e \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eØ15 mm pellets\u003c\/strong\u003e fit the \u003cstrong\u003eSample Holder Ø15\u003c\/strong\u003e \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe sample holders themselves are available with \u003cstrong\u003estainless steel 316L\u003c\/strong\u003e or \u003cstrong\u003etitanium contacts\u003c\/strong\u003e, ensuring reliable electrical connection during measurements. They include a silicone O‑ring (with PTFE available on request) to seal the pellet securely in place and prevent electrolyte leakage\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Relationship\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eThe \u003cstrong\u003esample holder\u003c\/strong\u003e provides the mechanical support, electrical contact, and sealing system.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThe \u003cstrong\u003epellet\u003c\/strong\u003e provides the active electrode surface.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTogether, they form a modular working electrode assembly compatible with OrigaLys instruments such as the \u003ca rel=\"noopener\" title=\"Rotating Disk Electrode\" href=\"https:\/\/celsa.com.au\/products\/rotating-disk-electrode-origatrod\" target=\"_blank\"\u003e\u003cstrong\u003eOrigaTrod\u003c\/strong\u003e\u003c\/a\u003e, \u003ca rel=\"noopener\" title=\"Electrode Holder Rod - StaTrod - Static Electrode\" href=\"https:\/\/celsa.com.au\/products\/electrode-holder-rod-statrod-static-electrode\" target=\"_blank\"\u003e\u003cstrong\u003eStaTrod\u003c\/strong\u003e\u003c\/a\u003e, and \u003cstrong\u003eEDI101\u003c\/strong\u003e.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThis modular design allows users to:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eSwap materials quickly for comparative studies\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReplace worn or contaminated surfaces without replacing the entire holder\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintain consistent geometry across experiments\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"940\" data-end=\"943\"\u003e\n\u003ch2\u003e\u003cstrong\u003eWhy This System Is Useful\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe OrigaTip pellet‑and‑holder system is ideal for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCorrosion studies\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaterial screening\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eElectrochemical sensor development\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSurface treatment evaluation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTeaching laboratories needing repeatable, interchangeable electrodes\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eIt ensures \u003cstrong\u003ehigh reproducibility\u003c\/strong\u003e, \u003cstrong\u003eclean electrical contact\u003c\/strong\u003e, and \u003cstrong\u003eflexibility\u003c\/strong\u003e across a wide range of electrochemical applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"945\" data-end=\"978\"\u003e\u003cbr\u003e\u003c\/h2\u003e","brand":"Origalys","offers":[{"title":"BDD \/ 8mm","offer_id":52140817809589,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"BDD \/ 15mm","offer_id":52140817842357,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"316L \/ 8mm","offer_id":52140817875125,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"316L \/ 15mm","offer_id":52140817907893,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Aluminum \/ 8mm","offer_id":52140817940661,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Aluminum \/ 15mm","offer_id":52140817973429,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Copper \/ 8mm","offer_id":52140818006197,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Copper \/ 15mm","offer_id":52140818038965,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Glassy Carbon \/ 8mm","offer_id":52140818071733,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Glassy Carbon \/ 15mm","offer_id":52140818104501,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Gold \/ 8mm","offer_id":52140818137269,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Gold \/ 15mm","offer_id":52140818170037,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Graphite \/ 8mm","offer_id":52140818202805,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Graphite \/ 15mm","offer_id":52140818235573,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Iron \/ 8mm","offer_id":52140818268341,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Iron \/ 15mm","offer_id":52140818301109,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Nickel \/ 8mm","offer_id":52140818333877,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Nickel \/ 15mm","offer_id":52140818366645,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Platinum \/ 8mm","offer_id":52140818399413,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Platinum \/ 15mm","offer_id":52140818432181,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Silver \/ 8mm","offer_id":52140818464949,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Silver \/ 15mm","offer_id":52140818497717,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Tungsten Steel \/ 8mm","offer_id":52140818530485,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Tungsten Steel \/ 15mm","offer_id":52140818563253,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"A37 Steel \/ 8mm","offer_id":52140818596021,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"A37 Steel \/ 15mm","offer_id":52140818628789,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/316L-15mm.png?v=1767341052"},{"product_id":"electrode-tips-origatip","title":"Electrode Tips - OrigaTip","description":"\u003ch2\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe OrigaTip range delivers a flexible, high‑performance solution for electrochemical research, offering a wide selection of interchangeable sensing tips built around a durable, chemically resistant PEEK body. Designed for seamless compatibility with OrigaLys rotating electrode systems, these tips let you choose the surface material and diameter that best match your experiment — including compact \u003cstrong\u003e2 mm\u003c\/strong\u003e \u0026amp; \u003cstrong\u003e3mm\u003c\/strong\u003e options and larger \u003cstrong\u003e5 mm\u003c\/strong\u003e formats. With consistent geometry, easy installation, and a broad variety of sensing surfaces, OrigaTip products give you the freedom to adapt quickly, work efficiently, and achieve reliable, high‑quality electrochemical results.\u003c\/p\u003e\n\u003cp\u003eCompatible with \u003ca title=\"RDE\" href=\"https:\/\/celsa.com.au\/products\/rotating-disk-electrode-origatrod\"\u003e\u003cstrong\u003eOrigaTrod\u003c\/strong\u003e\u003c\/a\u003e \u0026amp;\u003cstrong\u003e \u003ca title=\"Statrod\" href=\"https:\/\/celsa.com.au\/products\/electrode-holder-rod-statrod-static-electrode\"\u003eStaTrod\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Origalys","offers":[{"title":"Cobalt \/ 2mm","offer_id":52140888260789,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Cobalt \/ 3mm","offer_id":52153043681461,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Cobalt \/ 5mm","offer_id":52140888293557,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Carbon Steel XC38 \/ 2mm","offer_id":52141071138997,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Carbon Steel XC38 \/ 3mm","offer_id":52153043714229,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Carbon Steel XC38 \/ 5mm","offer_id":52141071171765,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Aluminum \/ 2mm","offer_id":52141071204533,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Aluminum \/ 3mm","offer_id":52153043746997,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Aluminum \/ 5mm","offer_id":52141071237301,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"70% Cu 30% Ni \/ 2mm","offer_id":52141083066549,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"70% Cu 30% Ni \/ 3mm","offer_id":52153043779765,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"70% Cu 30% Ni \/ 5mm","offer_id":52141083099317,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Stainless Steel 316L \/ 2mm","offer_id":52141083132085,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Stainless Steel 316L \/ 3mm","offer_id":52153043812533,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Stainless Steel 316L \/ 5mm","offer_id":52141083164853,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Tungsten \/ 2mm","offer_id":52141083197621,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Tungsten \/ 3mm","offer_id":52153043845301,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Tungsten \/ 5mm","offer_id":52141083230389,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Silver \/ 2mm","offer_id":52141083263157,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Silver \/ 3mm","offer_id":52153043878069,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Silver \/ 5mm","offer_id":52141083295925,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Rhodium \/ 2mm","offer_id":52141083328693,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Rhodium \/ 3mm","offer_id":52153043910837,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Rhodium \/ 5mm","offer_id":52141083361461,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Nickel \/ 2mm","offer_id":52141083394229,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Nickel \/ 3mm","offer_id":52153043943605,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Nickel \/ 5mm","offer_id":52141083426997,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Glassy Carbon \/ 2mm","offer_id":52141083459765,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Glassy Carbon \/ 3mm","offer_id":52153043976373,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Glassy Carbon \/ 5mm","offer_id":52141083492533,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Copper \/ 2mm","offer_id":52141083525301,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Copper \/ 3mm","offer_id":52153044009141,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Copper \/ 5mm","offer_id":52141083558069,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Titanium \/ 2mm","offer_id":52141083590837,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Titanium \/ 3mm","offer_id":52153044041909,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Titanium \/ 5mm","offer_id":52141083623605,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Zinc \/ 2mm","offer_id":52141083656373,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Zinc \/ 3mm","offer_id":52153044074677,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Zinc \/ 5mm","offer_id":52141083689141,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Iron \/ 2mm","offer_id":52141083721909,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Iron \/ 3mm","offer_id":52153044107445,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Iron \/ 5mm","offer_id":52141083754677,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Palladium \/ 2mm","offer_id":52141083787445,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Palladium \/ 3mm","offer_id":52153044140213,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Palladium \/ 5mm","offer_id":52141083820213,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Platinum \/ 2mm","offer_id":52141083852981,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Platinum \/ 3mm","offer_id":52153044172981,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Platinum \/ 5mm","offer_id":52141083885749,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Gold \/ 2mm","offer_id":52141083918517,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Gold \/ 3mm","offer_id":52153044205749,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"Gold \/ 5mm","offer_id":52141083951285,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/titaniumtip-5mm.png?v=1767355946"},{"product_id":"gold-microelectrodes-origasens-series","title":"Gold Microelectrodes – OrigaSens Series","description":"\u003ch2\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eGold microelectrodes from the OrigaSens range are precision‑engineered working electrodes designed for high‑sensitivity electrochemical measurements. Manufactured with exceptional dimensional accuracy, these microelectrodes provide stable, reproducible responses ideal for research laboratories, analytical chemistry, biosensing, corrosion studies, and kinetic investigations.\u003c\/p\u003e\n\u003chr data-end=\"943\" data-start=\"940\"\u003e\n\u003ch2 data-end=\"978\" data-start=\"945\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eHigh‑purity gold sensing surface\u003c\/strong\u003e for excellent conductivity and chemical inertness\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMicro‑scale internal diameters\u003c\/strong\u003e available in \u003cstrong\u003e10 µm, 25 µm, 40 µm, 50 µm, 100 µm, and 200 µm\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\u003cspan\u003e\u003cstrong\u003eStandard length: 50 mm\u003c\/strong\u003e across all models\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\u003cspan\u003e\u003cstrong\u003eExternal diameter: 5 mm\u003c\/strong\u003e, compatible with common electrode holders and cell setups\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\u003cspan\u003eDesigned for \u003cstrong\u003esteady‑state measurements\u003c\/strong\u003e, low‑noise signals, and rapid mass‑transport conditions\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for \u003cstrong\u003evoltammetry\u003c\/strong\u003e, \u003cstrong\u003eamperometry\u003c\/strong\u003e, and \u003cstrong\u003eimpedance spectroscopy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRobust construction for long‑term laboratory use\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e \u003cstrong\u003erange: 0–40 °C\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"940\" data-end=\"943\"\u003e\n\u003ch2\u003e\u003cstrong\u003eAvailable Gold Microelectrode Models\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ctable style=\"width: 100.036%; height: 177px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"text-align: center; width: 37.936%; height: 19.6px;\"\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"text-align: center; width: 23.2085%; height: 19.6px;\"\u003e\n\u003cspan\u003eInternal \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/th\u003e\n\u003cth style=\"text-align: center; width: 15.2669%; height: 19.6px;\"\u003e\u003cspan\u003eLength\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"width: 22.6537%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003eExternal \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"text-align: center; width: 37.936%; height: 19.6px;\"\u003e\n\u003cspan\u003eGold \u003c\/span\u003e\u003cspan\u003eMicroelectrode \u003c\/span\u003e\u003cspan\u003e– \u003c\/span\u003e\u003cspan\u003e10 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 23.2085%; height: 19.6px;\"\u003e\n\u003cspan\u003e10 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 15.2669%; height: 19.6px;\"\u003e\n\u003cspan\u003e50 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 22.6537%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003e5 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"text-align: center; width: 37.936%; height: 19.6px;\"\u003e\n\u003cspan\u003eGold \u003c\/span\u003e\u003cspan\u003eMicroelectrode \u003c\/span\u003e\u003cspan\u003e– \u003c\/span\u003e\u003cspan\u003e25 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 23.2085%; height: 19.6px;\"\u003e\n\u003cspan\u003e25 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 15.2669%; height: 19.6px;\"\u003e\n\u003cspan\u003e50 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 22.6537%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003e5 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"text-align: center; width: 37.936%; height: 19.6px;\"\u003e\n\u003cspan\u003eGold \u003c\/span\u003e\u003cspan\u003eMicroelectrode \u003c\/span\u003e\u003cspan\u003e– \u003c\/span\u003e\u003cspan\u003e40 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 23.2085%; height: 19.6px;\"\u003e\n\u003cspan\u003e40 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 15.2669%; height: 19.6px;\"\u003e\n\u003cspan\u003e50 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 22.6537%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003e5 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 37.936%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003eGold \u003c\/span\u003e\u003cspan\u003eMicroelectrode \u003c\/span\u003e\u003cspan\u003e– \u003c\/span\u003e\u003cspan\u003e50 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 23.2085%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003e50 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 15.2669%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003e50 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 22.6537%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003e5 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 37.936%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003eGold \u003c\/span\u003e\u003cspan\u003eMicroelectrode \u003c\/span\u003e\u003cspan\u003e– \u003c\/span\u003e\u003cspan\u003e100 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 23.2085%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003e100 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 15.2669%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003e50 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 22.6537%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003e5 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 37.936%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003eGold \u003c\/span\u003e\u003cspan\u003eMicroelectrode \u003c\/span\u003e\u003cspan\u003e– \u003c\/span\u003e\u003cspan\u003e200 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 23.2085%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003e200 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 15.2669%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003e50 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 22.6537%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003e5 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr data-start=\"940\" data-end=\"943\"\u003e\n\u003ch2\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eAnalytical electrochemistry\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTrace detection and low‑concentration analysis\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFast electron‑transfer studies\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBiosensor development\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCorrosion and materials research\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eMicrofluidic and small‑volume experiments\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"943\" data-start=\"940\"\u003e\n\u003ch2 data-end=\"978\" data-start=\"945\"\u003e\u003cstrong\u003eWhy Choose OrigaSens Gold Microelectrodes?\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThese electrodes offer a balance of precision, durability, and compatibility with a wide range of potentiostats and electrochemical cells. Their micro‑scale geometry enables enhanced mass transport and reduced capacitive currents, making them ideal for high‑resolution measurements where signal quality is critical.\u003c\/span\u003e\u003c\/p\u003e","brand":"Origalys","offers":[{"title":"10 µm","offer_id":52144685351093,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"25 µm","offer_id":52144685318325,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"40 µm","offer_id":52144685285557,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"50 µm","offer_id":52144685252789,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"100 µm","offer_id":52144685220021,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"200 µm","offer_id":52144685187253,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/GoldMicroelectrode-origalys.png?v=1767572994"},{"product_id":"silver-microelectrodes-origasens-series","title":"Silver Microelectrodes – OrigaSens Series","description":"\u003ch2\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eOrigaSens Silver Microelectrodes are high‑precision working electrodes designed for sensitive electrochemical measurements where silver’s unique electrochemical properties are required. These microelectrodes deliver stable, reproducible signals and are ideal for chloride‑based systems, reference electrode fabrication, biosensing, and analytical research.\u003c\/p\u003e\n\u003chr data-end=\"943\" data-start=\"940\"\u003e\n\u003ch2 data-end=\"978\" data-start=\"945\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eHigh‑purity silver sensing surface\u003c\/strong\u003e for excellent conductivity and well‑defined electrochemical behavior\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMicro‑scale internal diameters\u003c\/strong\u003e available in \u003cstrong\u003e25 µm, 50 µm, 100 µm, and 200 µm\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eStandard length: 50 mm\u003c\/strong\u003e across all models\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eExternal diameter: 5 mm\u003c\/strong\u003e, compatible with standard electrode holders and electrochemical cells\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eencapsulated construction for durability and long‑term laboratory use\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for \u003cstrong\u003evoltammetry\u003c\/strong\u003e, \u003cstrong\u003eamperometry\u003c\/strong\u003e, \u003cstrong\u003eimpedance spectroscopy\u003c\/strong\u003e, and \u003cstrong\u003esensor development\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eProvides low‑noise, steady‑state responses ideal for micro‑scale electrochemical studies\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e \u003cstrong\u003erange: 0–40 °C\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"940\" data-end=\"943\"\u003e\n\u003ch2\u003e\u003cstrong\u003eAvailable Silver Microelectrode Models\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ctable style=\"width: 100.036%; height: 98px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 37.5826%; height: 19.6px; text-align: center;\"\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"width: 24.0859%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003eInternal \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/th\u003e\n\u003cth style=\"width: 15.1025%; height: 19.6px;\"\u003e\u003cspan\u003eLength\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"width: 22.4739%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003eExternal \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 37.5826%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003eSilver \u003c\/span\u003e\u003cspan\u003eMicroelectrode \u003c\/span\u003e\u003cspan\u003e– \u003c\/span\u003e\u003cspan\u003e25 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 24.0859%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003e25 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 15.1025%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003e50 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 22.4739%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003e5 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 37.5826%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003eSilver \u003c\/span\u003e\u003cspan\u003eMicroelectrode \u003c\/span\u003e\u003cspan\u003e– \u003c\/span\u003e\u003cspan\u003e50 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 24.0859%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003e50 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 15.1025%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003e50 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 22.4739%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003e5 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 37.5826%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003eSilver \u003c\/span\u003e\u003cspan\u003eMicroelectrode \u003c\/span\u003e\u003cspan\u003e– \u003c\/span\u003e\u003cspan\u003e100 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 24.0859%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003e100 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 15.1025%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003e50 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 22.4739%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003e5 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 37.5826%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003eSilver \u003c\/span\u003e\u003cspan\u003eMicroelectrode \u003c\/span\u003e\u003cspan\u003e– \u003c\/span\u003e\u003cspan\u003e200 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 24.0859%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003e200 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 15.1025%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003e50 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 22.4739%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003e5 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003chr data-end=\"943\" data-start=\"940\"\u003e\n\u003ch2\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eChloride‑containing electrolyte systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAg\/AgCl reference electrode fabrication\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBiosensors and bioelectrochemical interfaces\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalytical electrochemistry and trace detection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMicrofluidic and small‑volume experiments\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eKinetic and mechanistic studies\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"943\" data-start=\"940\"\u003e\n\u003ch2\u003e\u003cstrong\u003eWhy Choose OrigaSens Silver Microelectrodes?\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eSilver microelectrodes offer a unique combination of high conductivity, predictable redox behavior, and compatibility with chloride‑based systems. OrigaSens electrodes are manufactured with tight dimensional tolerances, ensuring reproducibility and excellent signal stability. Their robust design and compatibility with standard laboratory setups make them a reliable choice for both research and applied electrochemistry.\u003c\/span\u003e\u003c\/p\u003e","brand":"Origalys","offers":[{"title":"25 µm","offer_id":52144688726197,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"50 µm","offer_id":52144688791733,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"100 µm","offer_id":52144688824501,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"200 µm","offer_id":52144688857269,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/SilverMicroelectrode-origalys.png?v=1767573943"},{"product_id":"iridium-microelectrodes-origasens-series","title":"Iridium Microelectrodes – OrigaSens Series","description":"\u003ch2\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eOrigaSens Iridium Microelectrodes are high‑performance working electrodes engineered for demanding electrochemical applications where extreme durability and chemical resistance are essential. Iridium’s exceptional hardness and corrosion resistance make these microelectrodes ideal for advanced research environments, aggressive electrolytes, and long‑term electrochemical studies.\u003c\/p\u003e\n\u003chr data-start=\"940\" data-end=\"943\"\u003e\n\u003ch2 data-start=\"945\" data-end=\"978\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eHigh‑purity iridium sensing surface\u003c\/strong\u003e offering outstanding chemical stability and resistance to harsh environments\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMicro‑scale internal diameter: 75 µm\u003c\/strong\u003e (current available model)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eStandard length: 50 mm\u003c\/strong\u003e for compatibility with most electrochemical cells\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eExternal diameter: 5 mm\u003c\/strong\u003e, suitable for standard electrode holders\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRobust construction for long service life\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eExcellent for \u003cstrong\u003evoltammetry\u003c\/strong\u003e, \u003cstrong\u003eimpedance spectroscopy\u003c\/strong\u003e, \u003cstrong\u003esensor development\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eProvides low‑noise, steady‑state microelectrode behavior with high reproducibility\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e \u003cstrong\u003erange: 0–40 °C\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"943\" data-start=\"940\"\u003e\n\u003ch2\u003e\u003cstrong\u003eAvailable \u003cspan\u003eIridium\u003c\/span\u003e Microelectrode Models\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ctable style=\"width: 100.036%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 37.3966%;\"\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"width: 24.4609%;\"\u003e\n\u003cspan\u003eInternal \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/th\u003e\n\u003cth style=\"width: 13.6549%;\"\u003e\u003cspan\u003eLength\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"width: 23.7325%;\"\u003e\n\u003cspan\u003eExternal \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.3966%;\"\u003e\n\u003cspan\u003eIridium \u003c\/span\u003e\u003cspan\u003eMicroelectrode \u003c\/span\u003e\u003cspan\u003e– \u003c\/span\u003e\u003cspan\u003e75 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 24.4609%;\"\u003e\n\u003cspan\u003e75 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 13.6549%;\"\u003e\n\u003cspan\u003e50 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 23.7325%;\"\u003e\n\u003cspan\u003e5 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003chr data-start=\"940\" data-end=\"943\"\u003e\n\u003ch2\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eHarsh or corrosive electrolyte systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHigh‑temperature electrochemical studies\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLong‑term stability testing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAdvanced sensor development\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalytical electrochemistry requiring extreme durability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eMicrofluidic and small‑volume experiments\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"940\" data-end=\"943\"\u003e\n\u003ch2\u003e\u003cstrong\u003eWhy Choose OrigaSens Iridium Microelectrodes?\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eIridium offers a unique combination of \u003cstrong\u003emechanical strength and\u003c\/strong\u003e \u003cstrong\u003echemical inertness\u003c\/strong\u003e, making it the material of choice for challenging electrochemical environments. OrigaSens microelectrodes are manufactured with tight tolerances, ensuring reproducible performance and compatibility with a wide range of potentiostats and laboratory setups. Their rugged design makes them ideal for researchers who need reliability under extreme conditions.\u003c\/span\u003e\u003c\/p\u003e","brand":"Origalys","offers":[{"title":"75 µm","offer_id":52144702161077,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/SilverMicroelectrode-origalys.png?v=1767573943"},{"product_id":"platinum-microelectrodes-origasens-series","title":"Platinum Microelectrodes – OrigaSens Series","description":"\u003ch2\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eOrigaSens Platinum Microelectrodes are precision‑engineered working electrodes designed for electrochemical applications requiring exceptional chemical stability, catalytic activity, and long‑term durability. Platinum’s wide potential window and robust performance make these microelectrodes ideal for both routine analytical work and advanced research environments.\u003c\/p\u003e\n\u003chr data-end=\"943\" data-start=\"940\"\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eHigh‑purity platinum sensing surface\u003c\/strong\u003e offering excellent electrochemical stability and catalytic behaviour\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMultiple micro‑scale internal diameters available:\u003c\/strong\u003e \u003cstrong\u003e10 µm, 25 µm, 50 µm, 100 µm, 200 µm\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eStandard length: 50 mm\u003c\/strong\u003e across all models\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eExternal diameter: 5 mm\u003c\/strong\u003e, compatible with standard electrode holders\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEncapsulated construction ensuring mechanical robustness and long service life\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIdeal for \u003cstrong\u003evoltammetry\u003c\/strong\u003e, \u003cstrong\u003eamperometry\u003c\/strong\u003e, \u003cstrong\u003eimpedance spectroscopy\u003c\/strong\u003e, and \u003cstrong\u003esensor development\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eProvides low‑noise, steady‑state microelectrode behaviour with high reproducibility\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e \u003cstrong\u003erange: 0–40 °C\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"940\" data-end=\"943\"\u003e\n\u003ch2\u003e\u003cstrong\u003eAvailable Platinum Microelectrode Models\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ctable style=\"width: 100.036%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center; width: 42.4231%;\"\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"text-align: center; width: 17.9868%;\"\u003e\n\u003cspan\u003eInternal \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/th\u003e\n\u003cth style=\"text-align: center; width: 15.1025%;\"\u003e\u003cspan\u003eLength\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"text-align: center; width: 23.7325%;\"\u003e\n\u003cspan\u003eExternal \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"text-align: center;\"\u003e\n\u003ctd style=\"width: 42.4231%;\"\u003e\n\u003cspan\u003ePlatinum \u003c\/span\u003e\u003cspan\u003eMicroelectrode \u003c\/span\u003e\u003cspan\u003e– \u003c\/span\u003e\u003cspan\u003e10 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 17.9868%;\"\u003e\n\u003cspan\u003e10 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 15.1025%;\"\u003e\n\u003cspan\u003e50 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 23.7325%;\"\u003e\n\u003cspan\u003e5 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: center;\"\u003e\n\u003ctd style=\"width: 42.4231%;\"\u003e\n\u003cspan\u003ePlatinum \u003c\/span\u003e\u003cspan\u003eMicroelectrode \u003c\/span\u003e\u003cspan\u003e– \u003c\/span\u003e\u003cspan\u003e25 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 17.9868%;\"\u003e\n\u003cspan\u003e25 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 15.1025%;\"\u003e\n\u003cspan\u003e50 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 23.7325%;\"\u003e\n\u003cspan\u003e5 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: center;\"\u003e\n\u003ctd style=\"width: 42.4231%;\"\u003e\n\u003cspan\u003ePlatinum \u003c\/span\u003e\u003cspan\u003eMicroelectrode \u003c\/span\u003e\u003cspan\u003e– \u003c\/span\u003e\u003cspan\u003e50 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 17.9868%;\"\u003e\n\u003cspan\u003e50 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 15.1025%;\"\u003e\n\u003cspan\u003e50 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 23.7325%;\"\u003e\n\u003cspan\u003e5 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"text-align: center;\"\u003e\n\u003ctd style=\"width: 42.4231%;\"\u003e\n\u003cspan\u003ePlatinum \u003c\/span\u003e\u003cspan\u003eMicroelectrode \u003c\/span\u003e\u003cspan\u003e– \u003c\/span\u003e\u003cspan\u003e100 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 17.9868%;\"\u003e\n\u003cspan\u003e100 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 15.1025%;\"\u003e\n\u003cspan\u003e50 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 23.7325%;\"\u003e\n\u003cspan\u003e5 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 42.4231%;\"\u003e\n\u003cspan\u003ePlatinum \u003c\/span\u003e\u003cspan\u003eMicroelectrode \u003c\/span\u003e\u003cspan\u003e– \u003c\/span\u003e\u003cspan\u003e200 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 17.9868%;\"\u003e\n\u003cspan\u003e200 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 15.1025%;\"\u003e\n\u003cspan\u003e50 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 23.7325%;\"\u003e\n\u003cspan\u003e5 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003chr data-end=\"943\" data-start=\"940\"\u003e\n\u003ch2\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCatalytic electrochemical reactions\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOxygen reduction\/oxidation studies\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFuel cell and hydrogen‑related research\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalytical electrochemistry and trace detection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMicrofluidic and small‑volume experiments\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eLong‑term stability and corrosion studies\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"943\" data-start=\"940\"\u003e\n\u003ch2\u003e\u003cstrong\u003eWhy Choose OrigaSens Platinum Microelectrodes?\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003ePlatinum is one of the most versatile electrode materials, offering a wide potential window, strong catalytic properties, and excellent resistance to corrosion. OrigaSens microelectrodes are manufactured with tight dimensional tolerances, ensuring reproducible performance and compatibility with a wide range of potentiostats and laboratory setups. Their rugged design and stable electrochemical behaviour make them a reliable choice for both routine and advanced research applications.\u003c\/span\u003e\u003c\/p\u003e","brand":"Origalys","offers":[{"title":"10 µm","offer_id":52144712810677,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"25 µm","offer_id":52144703733941,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"50 µm","offer_id":52144703766709,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"100 µm","offer_id":52144703799477,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true},{"title":"200 µm","offer_id":52144703832245,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/SilverMicroelectrode-origalys.png?v=1767573943"},{"product_id":"titanium-microelectrodes-origasens-series","title":"Titanium Microelectrodes – OrigaSens Series","description":"\u003ch2\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eOrigaSens Titanium Microelectrodes are durable, chemically resistant working electrodes designed for electrochemical applications where inertness, stability, and compatibility with aggressive environments are essential. Titanium’s excellent corrosion resistance and biocompatibility make these microelectrodes ideal for specialised research, sensor development, and studies involving reactive or complex electrolytes.\u003c\/p\u003e\n\u003chr data-start=\"940\" data-end=\"943\"\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eStability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMicro‑scale internal diameter: 50 µm\u003c\/strong\u003e (current available model)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\u003cspan\u003e\u003cstrong\u003eStandard length: 50 mm\u003c\/strong\u003e, suitable for most electrochemical cells\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eExternal diameter: 5 mm\u003c\/strong\u003e, compatible with standard electrode holders\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEncapsulated construction ensuring mechanical robustness\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for \u003cstrong\u003evoltammetry\u003c\/strong\u003e, \u003cstrong\u003eimpedance spectroscopy\u003c\/strong\u003e, \u003cstrong\u003esensor development\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eProvides stable, low‑noise microelectrode behaviour with high reproducibility\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e \u003cstrong\u003erange: 0–40 °C\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"943\" data-start=\"940\"\u003e\n\u003ch2\u003e\u003cstrong\u003eAvailable Titanium Microelectrode Models\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ctable style=\"width: 100.036%; height: 39.2px; margin-left: 0px; margin-right: auto;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 41.8914%; height: 19.6px; text-align: center;\"\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"width: 17.091%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003eInternal \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/th\u003e\n\u003cth style=\"width: 15.9907%; height: 19.6px; text-align: center;\"\u003e\u003cspan\u003eLength\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"width: 24.2718%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003eExternal \u003c\/span\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 41.8914%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003eTitanium \u003c\/span\u003e\u003cspan\u003eMicroelectrode \u003c\/span\u003e\u003cspan\u003e– \u003c\/span\u003e\u003cspan\u003e50 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 17.091%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003e50 \u003c\/span\u003e\u003cspan\u003eµm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 15.9907%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003e50 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 24.2718%; height: 19.6px; text-align: center;\"\u003e\n\u003cspan\u003e5 \u003c\/span\u003e\u003cspan\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003chr data-start=\"940\" data-end=\"943\"\u003e\n\u003ch2\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCorrosion and passivation studies\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eElectrochemistry in aggressive or reactive electrolytes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBiocompatible sensor development\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMicrofluidic and small‑volume experiments\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLong‑term stability testing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eAnalytical electrochemistry requiring inert, non‑catalytic surfaces\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"940\" data-end=\"943\"\u003e\n\u003ch2\u003e\u003cstrong\u003eWhy Choose OrigaSens Titanium Microelectrodes?\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eTitanium offers a unique combination of \u003cstrong\u003echemical inertness\u003c\/strong\u003e, \u003cstrong\u003emechanical strength\u003c\/strong\u003e, and \u003cstrong\u003ebiocompatibility\u003c\/strong\u003e, making it ideal for demanding electrochemical environments. OrigaSens microelectrodes are manufactured with tight dimensional tolerances, ensuring reproducible performance and compatibility with a wide range of potentiostats and laboratory setups. Their rugged design and stable electrochemical behaviour make them a reliable choice for specialised research applications.\u003c\/span\u003e\u003c\/p\u003e","brand":"Origalys","offers":[{"title":"50 µm","offer_id":52144713269429,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/files\/SilverMicroelectrode-origalys.png?v=1767573943"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/0025\/0549\/collections\/ELECTROCHEMICAL_CELL.png?v=1701300472","url":"https:\/\/celsa.com.au\/collections\/electrochemical-cells-1.oembed?page=3","provider":"Celsa","version":"1.0","type":"link"}