edge® Multiparameter EC, TDS, Salinity Meter - HI2030

edge® Multiparameter EC, TDS, Salinity Meter - HI2030

Regular price $1,283.80
Regular price $1,628.00 Sale price $1,283.80
Sale Sold out
Tax included.

The edge meter is only 0.5” thick yet rich in features to accommodate the needs of a vast amount of customers.

Manual

Multiparameter EC/TDS/Salinity Meter - HI2030

Specifications

SKU HI2030-01

Name

® Multiparameter EC/TDS/Salinity Meter - HI2030
pH Range -2.00 to 16.00 pH, -2.000 to 16.000 pH*
pH Resolution 0.01 pH, 0.001 pH*
pH Accuracy ±0.01pH, ±0.002 pH*
pH Calibration Automatic, up to 3 points (5 points*) calibration, 5 standard (7 standard*) buffers available (1.68*, 4.01 or 3.00, 6.86, 7.01, 9.18, 10.01, 12.45*) and 2 custom buffers*
pH Temperature Compensation Automatic -5 to 100º C (23 to 212º F) (using integral temperature sensor)
EC Range 0.00 to 29.99 µS/cm, 3.00 to 29.99 µS/cm, 30.0 to 299.9 µS/cm, 300 to 2999 µS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, up to 500.0 mS/cm, absolute conductivity ‡
EC Resolution 0.01 µS/cm, 00.1 µS/cm, 0.01 µS/cm, 0.01 mS/cm, 00.1 mS/cm
EC Accuracy ±1% of reading (±0.05 µS/cm or 1 digit, whichever is greater)
EC Calibration 1 Cell Factor calibration; 6 standards available: 84, 1413 µS/cm, 5.00, 12.88, 80.0, 111.8 mS/cm, 1 point offset: 0.00 µS/cm
TDS Range 0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150. to 1499. ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, up to 400.0 g/L absolute TDS ‡ (with 0.80 factor)
TDS Resolution 0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L
TDS Accuracy ±1% of reading (±0.03 ppm or 1 digit, whichever is greater)
TDS Calibration through EC calibration
EC/TDS Temperature Compensation Automatic -5 to 100 ºC (23 to 212 ºF); NoTC - can be selected to measure absolute conductivity.
Temperature Correction Coefficient 0.00 to 6.00% / ºC (for EC and TDS only). Default value is 1.90% / ºC
EC to TDS Conversion Factor 0.40 to 0.80 (default value is 0.50)
Salinity (% NaCl) Range 0.0 to 400.0% NaCl *
Salinity (% NaCl) Resolution 0.1% NaCl
Salinity (% NaCl) Accuracy ±1% of reading
Salinity (% NaCl) Calibration Single point with HI 7037L Standard
Salinity (PSU) Range 2.00 to 42.00 PSU *
Salinity (PSU) Resolution 0.01 PSU,
Salinity (PSU) Accuracy ±1% of reading
Salinity Range 0.0 to 80.0 g/L *
Salinity Resolution (ppt) 0.01 g/L
Salinity Accuracy (ppt) ±1% of reading
Dissolved Oxygen Measurement Type polarographic
Dissolved Oxygen Range 0.00 to 45.00 ppm (mg/L), 0.0 to 300.0%
Dissolved Oxygen Resolution 0.01 ppm (mg/L), 0.1%
Dissolved Oxygen Accuracy ±1.5% of reading
Dissolved Oxygen Calibration One or two points at 0% (HI 7040) and 100% (water saturated air)
Dissolved Oxygen Temperature Compensation 0.0 to 50.0 ºC (32.0 to 122 ºF)
Salinity Compensation 0 to 40 g/L 1 g/L
Altitude Compensation -500 to 4,000 m (-1640 to 13120’) 100 m (328’)
Temperature Range -20.0 to 120.0 ºC, -4.0 to 248.0 °F
Temperature Resolution 0.1 °C, 0.1 °F
Temperature Accuracy ±0.5 °C, ±1.0 °F
EC/TDS Probe HI 763100 EC/temperature probe
Logging Type Manual Log on Demand (Max. 200 logs); Manual Log on Stability (Max. 200 logs); Interval Logging 100 lots, Max. 600 logs/lot
Logging Memory Up to 1000 records
Connectivity 1 micro USB port for charging and PC connectivity, 1 USB port for storage
GLP yes
Battery Type/Life Built-in rechargeable battery with up to 8 hours of continuous use
Power Supply 5 VDC adapter (included)
Environment 0 to 50°C (32 to 122°F), RH max 95% non-condensing
Dimensions 202 x 140 x 12.7mm (8” x 5.5” x 0.5”)
Weight 250 g (8.82 oz)

 

accuracy and usability.

Digital Electrodes

edge electrodes are highly advanced, featuring a built-in microchip  

 

Sensor Check

When used with Hanna’s pH electrodes equipped with a matching pin, edge constantly checks the impedance of the pH measuring electrode to notify you in real time in the event of glass breakage. 

3.5 mm Probe Input

edge® is incredibly versatile. 

Wall Mount 

Cradle and Electrode Holder

edge® is incredibly thin and weighs only 8.8 oz., has an 8 hour battery life, and dual USB inputs.

Two USB Ports

edge includes one standard USB and a second micro USB port for file export and for charging when the cradle is not available.

Data Logging

edge allows you to store up to 1000 log records of data. Data sets include readings, GLP data, date and time.

Two Operating Modes

edge can be used in Extended or Basic Operating Modes. Extended Mode enables all features available while the Basic Mode reduces the amount of features to a very simple operation. For example, in extended mode edge offers 5 point calibration with 2 custom buffers while in basic mode calibration can only be performed to 3 points with 5 preprogrammed buffers.